Connecting to SHW hot waterThe cold water form the domestic supply is pre-heated in the GEO heat pump´s SHW tank to 45 ºC(factory setting 40 ºC), after which it is fed to the DHW tank in the Compact P, where it is heated to thedesired flow temperature.7612345GEO seen from the front GEO seen from below DHW tank SHW tank1. Supply flow to the solar coil in the SHW tank from GEO heat pump (the three-way-valve ist notmounted from factory)2. Return flow from the solar coil in the SHW tank to GEO heat pump3. Connection for domestic cold water supply4. Supply flow af pre-heated domestic hot water from the SHW tank to the DHW tank in Compact P5. Supply flow of domestic hot water from the DHW tank6. Connection for hot water circulation7. Sensor pocketConnecting to DHW hot waterIf the demand for domestic hot water is so great that the Compact P unit´s heat pump cannot cope, theGEO heat pump can be connected to the DHW tank´s solar coil to help heating up the domestic hotwater1234GEO seen from the front GEO seen from below DHW tank1. Supply flow to the solar coil in the DHW tank from GEO heat pump (three-way-valve as accessories)2. Return flow from the solar coil in the DHW tank to GEO heat pump3. Connection for domestic cold water supply4. Supply flow of domestic hot water from the DHW tankCompact P / Compact P Polar - GEO (English) BY NILAN47