NEC NEAX2000 IVS2 manuals
NEAX2000 IVS2
Table of contents
- installation procedure manual
- neax2000 ivs
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- regulatory information
- SAFETY INSTRUCTIONS
- NEAX2000 IVS
- INTRODUCTION
- ISSUE
- CHAPTER 1 GENERAL INFORMATION
- TRUNKING DIAGRAM
- SYSTEM CONFIGURATION
- Figure 1-3 2-PIM Configuration for Floor Standing Installation
- Figure 1-4 Maximum Configuration for Floor Standing Installation
- Wall Mounting Installation
- inch Rack Mounting Installation
- EQUIPMENT NAME AND FUNCTION
- Table 1-2 Installation Hardware Name and Function
- Control Card
- Application Processor Card
- Line/Trunk Card
- LINE CONDITIONS OF EACH TERMINAL
- MOUNTING CONDITIONS OF CIRCUIT CARD
- Control Card Mounting Conditions
- Application Processor Card Mounting Conditions
- Figure 1-10 Application Processor Card Mounting Slots (PIM1-7)
- Line/Trunk Card Mounting Conditions
- Figure 1-12 Line/Trunk Card Mounting Slots (PIM1-7)
- CHAPTER 2 INSTALLATION
- PRECAUTIONS
- Static Electricity Guard
- Figure 2-1 Static Electricity Guard (2 of 2)
- Procedure for Unplugging/Plugging Circuit Cards
- Turning Power ON
- Turning Power OFF
- PROCEDURE
- Figure 2-2 Procedure Flowchart (2 of 2)
- Stationary Equipment (For North America/Australia)
- UNPACKING
- WIRING AC CABLE TO TERMINALS
- Figure 2-4 AC CORD Wiring for Two-Frame Configuration
- Using Installation Cable
- Figure 2-6 Installation Cable Wiring for Two-Frame Configuration
- INSTALLATION OF MAIN EQUIPMENT
- Figure 2-7 Floor Space
- Figure 2-8 Cable Hole Location
- Figure 2-9 Floor Marking for BASE PLATE (for Fixed Equipment)
- Figure 2-11 Drilling Instructions for Anchor Bolt
- Figure 2-12 Connection of BASE and BASE PLATE
- Figure 2-13 Connection of PIM and BASE
- Figure 2-14 Placing PIM on BASE TRAY
- Figure 2-15 Connection of BUILD PLATE
- Figure 2-16 Connection of FRONT STOPPER
- Figure 2-17 Connection of Modules
- Figure 2-18 Installation of MOUNTING BRACKET
- Figure 2-19 Wall Marking for HANGER ASSEM
- Figure 2-20 Hanging PIM to HANGER ASSEM
- Figure 2-21 Detaching SIDE COVER (1 of 2)
- Figure 2-21 Detaching SIDE PANEL (2 of 2)
- Figure 2-22 Connection of 19" RACK BRACKET (A)
- Figure 2-23 Mounting PIM to 19-inch Rack
- Figure 2-24 Connection of 19" RACK BRACKET (B)
- Figure 2-25 Mounting Multiple-PIM to 19-inch RACK
- BUS Cable Connection
- POWER CABLE CONNECTION
- Connection of AC CORD-B
- Connection of DC Power Cable
- Figure 2-31 Mounting PZ-PW122 into PIM
- Figure 2-32 Cable Connection between PZ-PW121/PZ-PW122 and BWB
- Figure 2-33 PWR CA-A
- Figure 2-35 Connection of PWR CA-A Cables
- SUPPLY VOLTAGE CHECK AND HEAT RUN TEST
- Power Routing
- Checking for Supply Voltage
- Figure 2-36 Confirming Output Voltage
- BATTERY CONNECTION
- Internal Battery Connection
- Figure 2-37 Internal Battery Mounting (2 of 2)
- Figure 2-38 Internal Battery Connection for Multiple-PIM Configuration
- External / BATTM Battery Connection
- Figure 2-40 Battery Mounted into BATTM
- Figure 2-41 External/BATTM Battery Connection for Multiple-PIM Configuration
- CABLE RUNNING TO MDF
- MDF Cable
- Table 2-2 MDF Cables for each PIM
- Cable Running to External MDF
- Figure 2-45 Cable Running to the External MDF (1 of 2)
- Figure 2-45 Cable Running to the External MDF (2 of 2)
- TERMINATION OF CABLES ON MDF
- Location of Each LEN
- LTC Connector Pin Arrangement
- pim0 (ltc0 - ltc)
- pim1 (ltc0 - ltc)
- pim2 (ltc0 - ltc)
- pim3 (ltc0 - ltc)
- pim4 (ltc0 - ltc)
- pim5 (ltc0 - ltc)
- pim6 (ltc0 - ltc)
- pim7 (ltc0 - ltc)
- MDF Cross Connections
- Table 2-5 LTC0 - LTC3 MDF Cross Connection Information
- INSTALLATION OF PERIPHERAL EQUIPMENT
- Analog C.O. Trunk (COT)
- Tie Line Trunk (LDT/ODT)
- Figure 2-49 MDF Cross Connection for 4W E&M Trunk Card (1 of 2)
- Figure 2-49 MDF Cross Connection for 4W E&M Trunk Card (2 of 2)
- Figure 2-50 MDF Cross Connection for 2W E&M Trunk Card (1 of 2)
- Figure 2-50 MDF Cross Connection for 2W E&M Trunk Card (2 of 2)
- DID Trunk (AUC/DIT)
- Figure 2-52 MDF Cross Connection for 4 Line DID Trunk Card
- Digital Trunk Interface (DTI)
- Figure 2-54 MDF Cross Connection for DTI Card
- Figure 2-55 DTI Cable Connection via CONN Card
- Figure 2-56 Coaxial Cable Connection for DTI Card
- Figure 2-57 Connection of PZ-M542/PZ-M557 and PLATE
- Figure 2-58 Mounting of PZ-M542/PZ-M557 Card (1 of 2)
- Figure 2-58 Mounting of PZ-M542/PZ-M557 Card (2 of 2)
- Single Line Telephone (LC/AUC)
- Figure 2-60 MDF Cross Connection for Single Line Telephone (Long Line)
- SN716 DESKCON (DLC)
- Figure 2-65 Mounting of Handset Support to SN716 DESKCON (1 of 4)
- Figure 2-65 Mounting of Handset Support to SN716 DESKCON (2 of 4)
- Figure 2-65 Mounting of Handset Support to SN716 DESKCON (3 of 4)
- Figure 2-65 Mounting of Handset Support to SN716 DESKCON (4 of 4)
- Figure 2-66 Headset Installation for SN716 DESKCON
- Figure 2-67 Cable Connection to SN716 DESKCON
- Figure 2-68 AC-DC ADAPTER Connection to SN716 DESKCON
- Figure 2-69 PN-PW00 Card Connection to the SN716 DESKCON
- SN610/708/709/712 ATTCON (DLC)
- Figure 2-71 MDF Cross Connection for SN610 ATTCON (Long Line) (1 of 2)
- Figure 2-71 MDF Cross Connection for SN610 ATTCON (Long Line) (2 of 2)
- Figure 2-72 MDF Cross Connection for SN708/709/712 ATTCON (Standard Line)
- Figure 2-73 MDF Cross Connection for SN708/709/712 ATTCON (Long Line)
- Figure 2-74 Jack Set Installation for SN610/708/709/712 ATTCON
- Figure 2-75 Switch Setting on the SN610/708/709/712 ATTCON (1 of 2)
- Figure 2-75 Switch Setting on the SN610/708/709/712 ATTCON (2 of 2)
- Figure 2-76 Cable Connection to SN610/708/709/712 ATTCON
- Figure 2-77 Mounting of Handset Support to SN610/708/709/712 ATTCON
- Day/Night Mode Change by External Key (DK/MP)
- External TAS Indicator (DK/MP)
- Figure 2-80 MDF Cross Connection for TAS Indicator with Battery
- Figure 2-81 MDF Cross Connection for TAS Indicator with Battery (Ground Start)
- Paging Equipment (COT and DK/MP)
- Figure 2-82 Paging Equipment Connection Outline (2 of 2)
- Figure 2-83 MDF Cross Connection for Paging Equipment
- External Tone Source/Announcement Machine (DK/TNT/MP)
- Figure 2-84 External Tone Source/Announcement Machine Connection Outline
- External BGM Source (COT/TNT/MP)
- Figure 2-88 MDF Cross Connection for External BGM Sources
- Power Failure Transfer (AUC)
- Figure 2-90 MDF Cross Connection for PFT (AUC) (1 of 2)
- Figure 2-90 MDF Cross Connection for PFT (AUC) (2 of 2)
- Power Failure Transfer (8PFT)
- Figure 2-92 Connection of 25-Pair Cable and PZ-8PFTB
- Figure 2-93 PFT Connector Pin Assignment
- Figure 2-94 MDF Cross Connection for PFT (8PFT) (1 of 2)
- Figure 2-94 MDF Cross Connection for PFT (8PFT) (2 of 2)
- Alarm Display Panel (MP)
- Built-in SMDR (MP)
- RS RVS-4S CA-A/RS RVS-4S CA-C
- Figure 2-99 RS NORM-4 CA-A/RS NORM-4S CA-A
- SMDR/PMS/MCI/CIS Printer/Hotel Printer (AP00)
- Figure 2-101 SMDR/PMS/MCI Terminal Connection via MODEMs
- Figure 2-102 Printer Direct Connection
- Figure 2-104 RS PRT-15 CA-A/RS PRT-15S CA-A
- Table 2-7 RS-232C Connector Layout
- MOUNTING CIRCUIT CARDS
- Figure 2-106 Installation of the CARD STOPPER
- SYSTEM INITIALIZATION
- SYSTEM DATA ENTRY
- Cofirming Lamp Indication
- OPERATION TEST
- SYSTEM DATA SAVE
- CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
- Table 3-1 List of Control Cards
- PN-CP14 (MP)
- PN-CP15 (FP)
- PN-PW00 (EXTPWR)
- PZ-PW121 (AC/DC PWR)
- PZ-PW122 (DC/DC PWR)
- Table 3-2 List of Application Processor Cards
- PN-AP00-A (DBM)
- PN-AP00-B (AP00)
- PN-AP01 (AP01)
- PN-BRTA (BRT)
- PN-2BRTC (BRT)
- PN-CC01 (ETHER)
- PN-DAIA (DAI)
- PN-DAIB (DAI)
- PN-DAIC (DAI)
- PN-DAID (DAI)
- PN-DAIE (DAI)
- PN-DAIF (DAI)
- PN-24DTA-C (DTI)
- PN-30DTC-A (DTI)
- PN-IPTA (IPT)
- PN-24PRTA (PRT)
- PN-4RSTB (MFR)
- PN-4RSTC (CIR)
- PN-SC00 (CCH)
- PN-SC01 (DCH)
- PN-SC03 (ICH)
- PN-SC03-A (CSH)
- PZ-M537 (EXPMEM)
- PZ-M542 (CONN)
- PZ-M557 (CONN)
- Table 3-3 List of Line/Trunk Cards
- PN-2AMPA (AMP)
- PN-AUCA (AUC)
- PN-CFTA (CFT)
- PN-CFTB (CFT)
- PN-2COTD (COT)
- PN-4COTA-A (COT)
- PN-4COTB (COT)
- PN-4COTE (COT)
- PN-4COTF (COT)
- PN-4COTG (COT)
- PN-6COTJ (COT)
- PN-8COTQ (COT)
- PN-8COTR (COT)
- PN-8COTS (COT)
- PN-8COTT (COT)
- PN-2CSIA (CSI)
- PN-2CSIA-A (CSI)
- PN-4DATC (DAT)
- PN-2DITA (DIT)
- PN-4DITB (DIT)
- PN-DK00 (DK)
- PN-2DLCB/PN-2DLCN (DLC)
- PN-2DLCC (DLC)
- PN-4DLCF (DLC)
- PN-4DLCM (DLC)
- PN-4DLCQ (DLC)
- PN-8DLCL (DLC)
- PN-8DLCP (DLC)
- PN-2DPCB (DPC)
- PN-2ILCA (ILC)
- PN-4LCC (LC)
- PN-4LCD-A (LC)
- PN-4LCE (LC)
- PN-4LCF (LC)
- PN-4LCK (LC)
- PN-4LCL (LC)
- PN-4LCV (LC)
- PN-4LCW (LC)
- PN-8LCAA (LC)
- PN-2LDTA (LDT)
- PN-M03 (M03)
- PN-M10 (M10)
- PN-2ODTA (ODT)
- PN-2ODTB (ODT)
- PN-8RSTA (PBR)
- PN-TNTA (TNT)
- PN-4VCTH (VCT)
- PZ-8PFTB (PFT)
- PZ-VM00-M (VM)
- PZ-VM01 (VM)
manualsdatabase
Your AI-powered manual search engine