Go!Control Wireless Security System | Installation and Programming Guide58 Copyright © 2014 Linear LLCQ34: Cross Sensor Timeout, in Seconds(10-120)DEFAULT: 10 SecondsThe cross sensor timeout is the maximum period of timeallowed between violation of sensors 47 and 48 that willtrigger an alarm. If both sensors are violated within thistime period, an alarm will be triggered. If both sensors arenot violated within this time period, an alarm will not betriggered.NOTE: Cross sensor verification must be enabled withQ33: Cross Sensor 47‐48 for this feature to function.• The default setting for the cross sensor timeout is10 seconds.• To change the timeout duration, enter a valuedbetween 11 to 120 seconds.Q35: Abort Window Dialer Delay (0-2)DEFAULT: (1) 30 SecondsThe default minimum setting for ANSI/SIA CP‐01 complianceis 30 seconds.The delay time can be increased to 45 seconds withoutaffecting ANSI/SIA CP‐01 compliance only if thecombination of Q35 and Q6 or Q7 does not exceed one (1)minute.NOTE: The dialer delay can be disabled for each sensorwithout affecting ANSI/SIA CP‐01 compliance. See "RFSensor Programming Questions" on page 42.The dialer (digital communicator) delays calling the CentralStation to allow the user enough time to cancel a falsealarm before it is reported.• The default setting is (1) 30 Seconds.• To change the setting, select (0) 15 Seconds or (2)45 Seconds.Q36: Burglary Bell Cutoff (0 to 4)DEFAULT: (0) 4 MinutesWhen a burglary alarm is triggered, the bell will sound untilthe burglary bell cutoff time expires.• The default setting for the burglary bell cutoff is (0)4 Minutes.• To change the cutoff time, select an option below.Burglary Bell Cutoff Time(0) 4 Minutes(1) 8 Minutes(2) 12 Minutes(3) 16 Minutes(4) UnlimitedNOTE: The 24‐hour Auxiliary Alarm Zone (08) does notfollow the burglary bell cutoff time and will sound theControl Panel’s local alarm until a User Code is entered.The Auxiliary Alarm Zone does not trigger the externalsiren (if used).Q37: Fire Bell Cutoff (0-4)DEFAULT: (0) 4 MinutesWhen a fire alarm is triggered, the bell sounds until the firebell cutoff time expires.• The default setting (0) 4 Minutes sets the burglarybell cutoff to four (4) minutes.• To change the fire bell cutoff time, select an optionbelowFire Bell Cutoff Time(0) 4 minutes(1) 8 minutes(2) 12 minutes(3) 16 minutes(4) UnlimitedQ38: Time to Detect AC Loss, in Minutes(0-30)DEFAULT: (10) 10 MinutesWhen AC power is lost, they system displays a power lossalert after the specified time length. When power isrestored, the alert is automatically cleared after one (1)minute.• The default detection timer for displaying the alertmessage is (10) 10 Minutes.• To change the detection timer, enter a valuebetween 0 to 30 minutes.NOTE: After the AC power alert is displayed or clears,the AC power loss report or AC power restore reportcan be sent to the Central Station immediately, or at arandom time, see Q39: Random AC Loss Report Time.NOTE: The Control Panel’s AC Power Icon immediatelydisplays the power status. See “AC Power On/OFF” onpage 29.