3Com VCX V7111 Fast Track Installation Guide 313 At the prompt type “conf” and press enter; the configuration command shell is activated.4 To check the current network parameters, at the prompt, type “GCP IP” and press enter;the current network settings are displayed.5 Change the network settings by typing: “SCP IP [ip_address] [subnet_mask][default_gateway]” (e.g., “SCP IP 10.13.77.7 255.255.0.0 10.13.0.1”); the new settingstake effect on-the-fly. Connectivity is active at the new IP address.Note: This command requires you to enter all three network parameters (separated byspaces).6 To save the configuration, at the prompt, type “SAR” and press enter; the VCX V7111restarts with the new network settings.Restoring Networking Parameters to their Initial StateYou can use the ‘Reset’ button to restore the VCX V7111 networking parameters to theirfactory default values (described in Table 10 on page 27) and to reset the username andpassword.Note that this process also restores the VCX V7111 parameters to their factory settings,there you must your previously backed up ini file or the default ini file (received with thesoftware kit) to set them to their correct values.To restore networking parameters to their initial state, follow these steps:1 Disconnect the VCX from the power and network cables.2 Reconnect the power cable; the gateway is powered up. After approximately 45 secondsthe Ready LED turns to green and the Control LED blinks for about 3 seconds.3 While the Control LED is blinking, press shortly on the reset button (located on the leftside of the front panel; the gateway resets a second time and is restored with factorydefault parameters (username: “Admin”’ password: “Admin”).4 Reconnect the network cable.5 Load your previously backed-up ini file, or the default ini file (received with the softwarekit). To load the ini file via the Embedded Web Server, see Chapter 5: Restoring andBacking Up the VCX V7111 Configuration on page 43.Accessing the Embedded Web ServerTo access the Embedded Web Server, follow these steps:1 Open a standard Web-browsing application such as Microsoft™ Internet Explorer™(version 6.0 and higher) or Netscape™ Navigator™ (version 7.0 and higher).2 In the URL field, specify the IP address of the VCX V7111 (e.g., http://10.1.10.10 for theVCX V7111 FXS); the Embedded Web Server’s ‘Enter Network Password’ screenappears (Figure 16 on page 32).