How to maintain or verify a disk arraywww.3ware.com 37Figure 16. Delete Disk Array DisplayNavigate to the Delete Array button and press Enter to bring up the DeleteDisk Array display. Check that the correct drives are listed.Select the OK key to confirm deleting the array or Cancel to reject it. Recallthat the array is not actually deleted and no data will be overwritten until youhave finished making all your changes and selected the F8 key.How to maintain or verify a disk arrayThe Maintain Disk Array (see Figure 17) shows the current disk array con-figuration that you have selected. The array’s Write Cache State can bechanged. Refer to Select write cache properties paragraph in the Creating adisk array section. Verify Array can be specified as no or yes. The default isno. Yes launches a foreground process that checks the data integrity of a faulttolerant array. If the verify array process determines that the mirrored drivesare not identical or the parity is not correct, initialization of the array islaunched.Restore Initial ValuesPrevious/Next Toggle Hot SpareCancelSelect/DeselectDoneAlt-F1F6EnterF8$EscHelp3 w a r e D i s k A r r a y C o n f i g u r a t i o nCreate Array Delete Array Maintain Array Rebuild ArrayAvailable Drives:Disk Arrays:*Array Unit 0 - 4 drive 64K RAID 0 120.0GBPort 0 - QUANTUM FIREBALLP LM30 30.0GBPort 1 - QUANTUM FIREBALLP LM30 30.0GBPort 2 - QUANTUM FIREBALLP LM30 30.0GBPort 3 - QUANTUM FIREBALLP LM30 30.0GB