Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Additional instructions and notes
- Grounding
- General safety in operation
- Quick installation and commissioning flowchart
- Terms and abbreviations
- Related documents
- Layout
- Frame size R3
- Frame R4...R8
- Overview of power and control connections
- External control connecting terminal, Frame size R0...R2
- External control connecting terminal, Frame size R3...R5
- External control connection terminals, frames R6...R8
- Control panel
- Type designation label
- Locations of the labels on the drive
- Type designation key
- Checking the installation site
- Required tools
- Unpacking and examining delivery, frames R3...R4
- Unpacking and examining delivery, frames R5
- Unpacking and examining delivery, frames R6...R8
- Installing the drive
- Installing the drive vertically, frame size R3...R4
- Installing the drive vertically, frames size R5...R8
- Installing the drive vertically side by side
- Other regions
- Alternative power cable types
- Recommended power cable types
- Conduit
- Signals in separate cables
- Separate control cable ducts
- Protecting the motor and motor cable in short-circuits
- Implementing the Safe torque off function
- Switching the motor power supply from drive to direct-on-line
- Switching the motor power supply from direct-on-line to drive
- Input power cable
- Checking the compatibility with IT (ungrounded) and corner-grounded TN systems
- Frames R0...R3
- Frames R4...R8
- Connecting the power cables
- Connection procedure, frames R0...R2
- electrical installation
- Finalization
- Motor cable
- Notes
- Connection procedure, frames R5...R8
- Notes for frame R8
- DC connection
- Default control connections for the ABB standard macro
- PNP configuration for digital inputs
- Connection for obtaining 0...10 V from analog output 2 (AO2)
- DI5 as frequency input
- Safe torque off (X4)
- R0...R2
- R3...R5
- R6...R8
- Option slot 1 (fieldbus adapter modules)
- Reinstalling covers, frame size R3, R4
- Recommended annual maintenance actions by the user
- Heatsink
- Replacing the cooling fan, frames size R0...R4
- Replacing the main cooling fan, frames size R6...R8
- Replacing the auxiliary cooling fan, frames R6...R8
- Capacitors
- LEDs
- Definitions
- Sizing
- Switching frequency derating
- Fuses (IEC)
- gG fuses
- gR fuses
- Circuit breakers
- Dimensions, weights and free space requirements
- Thermal losses, cooling data and noise
- Terminal and lead-through data for the power cables
- Terminal and lead-through data for the control cables
- Electrical power network specification
- EMC compatibility and motor cable length
- Brake resistor connection data for frames R0...R3
- Auxiliary circuit power consumption
- Degree of protection
- Materials
- CE marking
- Compliance with the EN 61800-3:2004 + A1:2012
- Category C3
- Frame R0, IP20
- Frame R1, IP20
- Frame R3, IP20
- Frame R5, IP20
- Frame R6, IP20
- Frame R7, IP20
- Frame R8, IP20
- Selecting and routing the brake resistor cables
- Placing the brake resistor
- Mechanical installation
- Resistor braking, frames R4...R8
- What this chapter contains
- Compliance with the European Machinery Directive
- Connection principle (R0...R2)
- Connection principle (R3-R8)
- Activation switch
- Grounding of protective shields
- Acceptance test reports
- Maintenance
- Safety data
- Abbreviations
- Declaration of conformity
- Description, installation and technical data of the FOCH filters
|
PE terminalsU1. V1. W1 / U2. V2. W2 / R+. R- / DC+. DC- terminalFramesizeDesig.ACS560 torquemaxtorqueMax.( (single core and/multi-core )min. ( single coreand / multicore)N·mmm2lbf·ftN·mAWGmm2AWGmm21.260.40.5...0.686/6180.2/0.2R005A6-41.260.40.5...0.686/6180.2/0.2R007A2-41.260.40.5...0.686/6180.2/0.2R009A4-41.260.40.5...0.686/6180.2/0.2R112A6-41.261.01.2...1.546/16200.5/0.5R2017A-41.261.01.2...1.546/16200.5/0.5R2025A-41.5103.32.5...4.5235/25200.5/0.5R3033A-41.5103.32.5...4.5235/25200.5/0.5R3039A-41.5163.32.5...4.5235/25200.5/0.5R3046A-41.5163.04.0150/50200.5/0.5R4062A-41.5164.15.6150/50200.5/0.5R4073A-42.2254.15.62/070106R5088A-42.2354.15.62/070106R5106A-49.85022.130300 MCM150325R6145A-49.87022.130500 MCM2403/095R7169A-49.87022.130500 MCM2403/095R7206A-49.82x3529.5402x300MCM2x1502x1/02x50R8246A-49.82x5029.5402x300MCM2x1502x3/02x50R8293A-4Terminal and lead-through data for the control cablesControl cable lead-throughs, wire sizes and tightening torques (T) are given below.Control TerminalFramesizeDesig. ACS560DI. AI/O. AGND. RO. STO+24V. DCOM.DGNDT (N·m)mm2T (N·m)mm23 phases UN = 400V (380…480V)0.5...0.60.14...1.50.5...0.60.14...1.5R002A6-4...09A4-40.5...0.60.14...1.50.5...0.60.14...1.5R112A6-40.5...0.60.14...1.50.5...0.60.14...1.5R2017A-4. 025A-40.5...0.60.14...1.50.5...0.60.2...2.5R3033A-4...046A-40.5...0.60.14...1.50.5...0.60.2...2.5R4062A-4. 073A-40.5...0.60.14...1.50.5...0.60.2...2.5R5088A-4. 106A-40.5...0.60.14...1.50.5...0.60.14...2.5R6145A-40.5...0.60.14...1.50.5...0.60.14...2.5R7169A-4. 206A-40.5...0.60.14...1.50.5...0.60.14...2.5R8246A-4. 293A-4118 Technical data
PreviousNext |