24PL15 - ANTI-WRINKLE TIMING1. Guard Delay Time (GdLY)This program controls the dwell (stop) time and activation of anti-wrinkle “Guard On Time” (“Gont”). Thedwell (stop) time can be programmed from a minimum of 1 minute to a maximum of 9 minutes in 1 minuteincrements.2. Guard On Time (Gont)The setting controls the amount of time that the basket (tumbler) will turn, without heat, when theAnti-Wrinkle is active (“Grd”). The “Guard On Time” (“Gont”) is programmable from a minimum of1-second to a maximum of 99-seconds in 1-second increments.PL16 - ACTIVE GUARD TIME (AGt)This program controls the maximum time that the Anti-Wrinkle Program will be active and is programmable froma minimum of 1 minute to a maximum of 99 minutes in 1 minute increments.PL17 - “A” and “b” FACTORSThis location will include the “Auto-Cycle” parameters. These parameters are necessary to allow the Phase 5microprocessor controller (computer) to calculate the percentage of dryness in the basket (tumbler). The “A”Factor is adjustable from 1 to 99.These parameters are the factors that the Phase 5 microprocessor controller (computer) utilizes when programmedfor an “Automatic Drying Cycle.” The “A” Factor slope program, pertains to the thermal characteristic of eachmodel dryer. The “b” Factor, heat loss (offset) program, also pertains to the thermal characteristics of eachmodel dryer. This factor setting is dependent upon the model dryer and type of heating unit.The “A” and “b” Factors have not been preprogrammed by the factory and must be programmed if the Phase5 microprocessor controller (computer) programming is changed to be used in the Automatic Mode. The “A”and “b” Factors must be programmed for the particular dryer model and heating unit as shown in the “A” and“b” Factor (parameter) table on page 60 of this manual.