39Summary: LO Temp is programmable from a minimum of 100° F to a maximum of 190° F in ten-degree incrementsor from a minimum of 38° C to a maximum of 88° C in five-degree increments.For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from aminimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C toa maximum of 77° C in five-degree increments.For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable froma minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° Cto a maximum of 71° C in five-degree increments.H. PROGRAM LOCATION 05 (PL05)LO TempLocation to be viewed/changed.Press “Perm Press” key.Display will read “LO°F,” LO Tempstatus for 3-seconds and then theactual temperature programmed.If no changes, press “Perm Press”key otherwise press “HI” or “LO”keys and then “Perm Press” key.LO°FPerm Press120F HI TempPerm PressLO TempRefer to Section V for instructionson entering program locations.(Wait 3-Seconds)Automatically goes into PL06Program without PL06 Display ModePL05Continued on next pageTemperature Decrease Temperature Increase