AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000Page 262 01/2011 Description des sous-ensembles4.14.1.3 Physical description (see Figure 4.51 )ConnectorsTABLEAU 4.70 DESCRIPTION OF THE LA16X CARD CONNECTORSIndicatorsThis card has no signalling indicator.4.14.1.4 Hardware configurationThis card has no configuration microswitch.4.14.1.5 Installation and wiringThe LA16X card can be hot-plugged in an AXD, AXL, AXS or AXS12 iPBX in normaloperation.The requirements for connecting an analogue terminal are:• the voltage and current measured across the station during conversation must be:U > 12,4 V and I > 25 mA,• line resistance (taking the set into account): 600 Ohms,• all the analogue terminals connected to the PBX must be configured for Zrefimpedance and self-regulation.This card must be connected with cables with the following references: HG4765B,HG4765C or HG4731.The minimum diameter of the cables has to be 26AWG (0.4mm).NAME FUNCTION/CHARACTERISTIC CONTACTSJ1 96-pin connector:backplane connectionL0 to L15 RJ45 connectors: each socketprovides one connection to ananalogue set• Pin 4:analogue set (i)+• Pin 5:analogue set (i)-• Pins 1, 2, 3, 6, 7, and 8:NC8 1