19You can use the FRU/SDR Load Utility (see “FRU/SDR Load UtilityDescription” on page 76) to initialize or update the FRU and SDRinformation. Acer server boards are shipped from the factory withsome sensors disabled, because the actual configuration of the chassisis only determined when the user completes the system configuration.Chassis-specific information in the FRU, such as chassis part number, isalso absent. For these reasons, it is important to run the FRU/SDR LoadUtility as part of the system setup process. You should also run the FRU/SDR Load Utility whenever you change the number of fans, processors,or power supplies in the server.System Event LogThe BMC manages a system event log (SEL), where it records significantor critical system events. Such events include temperatures and events.The BIOS, software, and other devices can also log events by sendingmessages to the BMC. The SEL is stored in nonvolatile storage.You can view the current contents of the SEL by using the System SetupUtility (see “Viewing the System Event Log” on page 63).Platform Event ManagementEvents can trigger alerts and other actions by the BMC. The server isconfigured with the following set of standard events:• Temperature sensor out of range• Voltage sensor out of range• Fan failure• Chassis intrusion• Power supply fault• BIOS uncorrectable ECC error• BIOS POST error• Processor fault resilient booting (FRB) failure• Fatal nonmaskable interrupt (NMI) from a source other than thefront panel switch• Watchdog timer reset, power down, or power cycle• System restart (reboot)Alerts can take either of these forms: