65• Save As: Saves the currently loaded FRU data to a file.• Properties: Displays the number of FRU devices in the system andthe number being displayed. Only FRU devices with valid FRU areasare displayed.• Reload: Refreshes the display by reading the current FRU entriesfrom the server.Viewing Sensor Data RecordsTo view the Sensor Data Records (SDR):1 From the SSU Main window, choose SDR Manager.When you start the SDR Manager, it automatically loads the SDRentries from non-volatile memory.The SDR Manager window has a navigation pane on the left thatdisplays, in a tree format, the sensor data records. The tree hascategories for each type of record. Clicking on a category expandsor collapses a list of SDRs for that category. Clicking on anindividual SDR displays the information for that SDR in thepresentation pane in the upper right. The description pane in thelower right displays a description of the currently selected SDRtype.2 Use the F4 and F5 keys to scroll the window contents to the leftand right to view all of the columns.3 Use the File and SDR menu items to work with the SDRinformation:• Open: Views data from a previously saved SDR file.• Save As: Saves the currently loaded SDR data to a file.• Properties: Displays information about the SDR, including IPMIversion, number of SDR entries, time stamps for changes to theSDR information, and free space remaining.• Reload: Refreshes the display by reading the current SDR entriesfrom the server.Updating System Firmware and BIOSUsing the SSU, you can update the BIOS, update the firmware, andverify the firmware. Procedures for each are given below. You can alsoupdate the BIOS and firmware without using the SSU.