224. Set up and cut along five inches of the barstock.5. Using a micrometer, measure the bar stocknext to the chuck and at the end. Themeasurement should be the same.6. If the measurements are not the same andadjustment is required, loosen hex socketcap screw (A, Fig.24), which holds theheadstock to the bed. Do not loosencompletely; some drag should remain.7. Adjust two screw nuts (B, Fig.24) locatedon the end gear side of the headstock.Loosen one and tighten the other. Makeanother cut. Keep adjusting screw nuts aftereach cut until the bar stock measurementsare the same. Tighten all headstock screws.Removing Gap Section1. To remove gap section, locate two nuts (A,Fig.25) in the center of the gap section.2. Using an open-end wrench, tighten the twonuts. This will cause the taper pins torelease. Remove the taper pins.3. Remove sox hex socket cap screws (B,Fig.25) with a hex key wrench.4. Gap section can now be removed.Installing Removable Gap Section1. Clean the bottom and the end of the gapsection thoroughly.2. Set gap section in place and align.3. Remove nuts from the taper pins.4. Slide taper pins in their respective holesand seat using a mallet. Install nuts on thetaper pins finger tight.5. Install six-socket hand cap screw andtighten securely.Fig.24Fig.25