A:\> AFU UPDATE /C 0Adaptec Flash Utility V4.0-0 B5749(c)Adaptec Inc. 1999–2005. All Rights Reserved.Updating Controller 0 (Adaptec RAID 31205)Reading flash image file (Build 5749)AFU is about to update firmware on controllers Adaptec RAID51645***PLEASE DO NOT REBOOT THE SYSTEM DURING THE UPDATE***This might take a few minutes.Writing Adaptec RAID 51645 (4MB) Flash Image to controller0...OK.Verifying...OKPlease restart the computer to allow firmware changes to takeeffect.VerifyCompares the contents of each of the flash components on a RAID controller to the correspondingimage in a UFI file, and indicates whether they match. After using the VERIFY command, you must restartthe computer.The command syntax for the VERIFY command is as follows:AFU VERIFY [/C] [/D ]This example shows a typical system response after a VERIFY command.A:\> AFU VERIFY /C 0Adaptec Flash Utility V4.0-0 B5749 (c)Adaptec Inc. 1999–2005.All Rights Reserved.Reading flash image file (Build 5748) Controller #0: AdaptecRAID 51645ROM: Checksum: 797B [VALID] (Build 5748)File: Checksum: 797B [VALID] (Build 5748)Image Compares CorrectlyVersionDisplays version information about the flash components on a RAID controller. After using the VERSIONcommand, restart your computer.The command syntax for the VERSION command is:AFU VERSION [/C]This example displays version information about all supported RAID controllers.A:\> AFU VERSION /C 0Adaptec Flash Utility V4.0-0 B5749 (c)Adaptec Inc. 1999–2005.All Rights Reserved.Version Information for Controller #0 (Adaptec RAID 51645)ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2005A:\> AFU VERSION /C ALL82Proprietary and Confidential to PMC-Sierra, Inc.Document No.: CDP-00277-01-A Rev. A, Issue:Serial Attached SCSI RAID Controllers Installation and User's Guide