3-14 Receiving and Installation MN715JAnalog OutputOne programmable analog output is provided at J4-10 and J4-9. The outputis scaled 0 - 5 VDC, 0 - 10 VDC, 4-20mA or 0-20mA. The output function isprogrammed in the Level 1 Output block, Analog Out parameter value. Thescaling of the output is programmed in the Level 1 Output block, AnalogScale.Relay OutputsOne normally open (N.O.) and one normally closed (N.C.) relay contact isavailable at terminals J4-1, J4-2 and J4-3. J4-2 is relay common. The outputis programmable in the Level 1 Output block, Relay Output parameter.1. Connect the N.O. contact to another circuit by attaching the wires to J4-1and J4-2.2. Connect the N.C. contact to another circuit by attaching the wires to J4-3and J4-2.External Trip InputTerminal J4-17 is available for connection to a normally closed thermostat oroverload relay in some operating modes as shown in Figure 3-9. Thethermostat or overload relay should be a dry contact type with no poweravailable from the contact. If the motor thermostat or overload relay activates,the control will automatically shut down and give an external trip fault.The optional relay (CR1) shown provides the isolation required. The N.O.contact is closed when power is applied to the relay and the motor is cold.Connect the external trip input wires to J4-17 and J4-18. Do not place thesewires in the same conduit as the motor power leads.To activate the external trip input, the external trip parameter in the Level 2Protection Block must be set to ìONî.Figure 3-9 External Trip Input Connection !7 % 1% !( $( $%( /'%,1$ (/& ,(#$$%01(/(1##&$,(1'+& 0!/( ,(!! "#$% &! , 1(-,,(# &6*'//%,,/$% &$0!%$%0<1$%('$%) ,, ###$ &6 ,#'$+,+$'2& 69(%1--:& 69,$,:B% &//+& ,#'$% / 6 - <1$, -6 $% &&'$' &,<1$+ &%