Control Wiring 5-3MN762S5.3 Analog and Digital Input ConfigurationsParameters P1-07 and P1-08 can be set to allow various operating modes. Following are settings forthese parameters.5.3.1 Terminal Strip Mode (P1-07 = 0)Table 5-3 Parameter P1-08 Control of Digital Inputs when P1-07=0P1-08 Digital In 1(Term 2) Digital In 2(Term 3) Digital In 3(Term 4) Analog Input(Term 6)0Open: Stop Open: Bipolar analogspeed reference Open: Preset Speed 1Bipolar analog inputClosed: Run Closed: Preset speedreference Closed: Preset Speed 21Open: Stop Open: Preset Speed 1 Open: Preset Speed 1/2 Open: Preset Speed1/2/3Closed: Run Closed: Preset Speed 2 Closed: Preset Speed 3 Closed: PresetSpeed 42Open: StopClosed: RunDigital Input 2 (Term 3) Digital Input 3(Term 4)Bipolar analoginput (Term 6) Speed Set pointOpen Open Open Preset Speed 1Closed Open Open Preset Speed 2Open Closed Open Preset Speed 3Closed Closed Open Preset Speed 4Open Open Closed Preset Speed 5Closed Open Closed Preset Speed 6Open Closed Closed Preset Speed 7Closed Closed Closed Preset Speed 83 Open: Stop Open: Forward Open: Bipolar analog ref Bipolar analog inputClosed: Run Closed: Reverse Closed: Preset Speed 14 Open: Stop Open: Forward Analog input 2(Speed Reference)Bipolar analog input(Torque reference)Closed: Run Closed: Reverse5 Open: StopClosed: RunOpen: ForwardClosed: ReverseDigital Input 3(Term 4)Bipolar analoginput (Term 6) Speed Set pointOpen Open Preset Speed 1Closed Open Preset Speed 2Open Closed Preset Speed 3Closed Closed Preset Speed 46 Open: StopClosed: RunOpen: ForwardClosed: ReverseExternal trip input:Bipolar analog inputOpen: TripClosed: No Trip