OverviewEZ-SCREEN LPInstruction Manual Components and Specifications2.3 CordsetsMachine interface cordsets provide power to the first emitter/receiver pair. Sensor interconnect cables provide power tosubsequent emitters and receivers in the cascade. Only cordsetswith yellow PVC cable and black overmolds are listed; forcordsets with black PVC cables and overmolds, add suffix “B” tothe model number (e.g., RDLP-815DB).A removable disconnect (RD) fitting is required to connectdirectly to the sensor housing. QD fittings are used for cable-to-cable interconnections and connections with other devices.RD to Flying Leads CordsetsRemovable disconnect (RD) connector on one end; unterminated(cut to length) on other.ModelNumber Length Wire Banner CordsetColor CodeFor Emitters and Receivers Color FunctionRDLP-815DRDLP-825DRDLP-850DRDLP-875DRDLP-8100D4.6 m (15.1')8 m (26.2')15.3 m (50.2')23 m (75.5')30.5 m (100.1')8-conductorcable,22 AWG/0.33 mm²Bn +24V dcOr/Bk EDM 2 (Aux)Or EDM 1Wh OSSD 2Bk OSSD 1Bu 0V dcGn/Ye Gnd/ChassisVi ResetRD to Flying Leads Cordsets (E-Stop/Interlock Connections)Used to connect devices to receiver cascade input RDconnection. Removable disconnect (RD) connector on one end;unterminated (cut to length) on other. See Figures 7-8, 7-9, and 7-10.For Cascade Receivers Only Color E-StopFunctionRDLP6G-415DRDLP6G-425DRDLP6G-450D4.6 m (15.1')8 m (26.2')15.3 m (50.2')4-conductorcable,22 AWG/0.33 mm²Bn Ch 1aWh Ch 2aBk Ch 1bBu Ch 2bRD to M12/Euro QD CordsetsUsed to interconnect SLPC.. and SLSC.. (standard EZ-SCREEN)emitters or receivers in a cascade, or for use with a mating M12/Euro QD cordset, such as QDE.., DEE2R-.., or CSB-.., listed onpage 10). See Section 7.4 for maximum cascade cordset lengths.Model Length Wire TerminationDELPE-81DDELPE-83DDELPE-88DDELPE-815DDELPE-825DDELPE-850DDELPE-875DDELPE-8100D0.3 m (1')1 m (3.3')2.5 m (8.2')4.6 m (15.1')8 m (26.2')15.3 m (50.2')23 m (75.5')30.5 m (100.1')8-conductorcable,22 AWG/0.33 mm²RD-styleremovabledisconnect fittingat one end, maleM12/Euro QDfitting at the otherRD to RD CordsetsUsed to interconnect multiple SLPC.. emitters or receivers in acascade. See Section 7.4 for maximum cordset lengths.Model Length Wire TerminationDELP-110EDELP-111EDELP-113EDELP-118EDELP-1115EDELP-1125EDELP-1150EDELP-1175EDELP-11100E0.05 m (0.2')0.3 m (1')1 m (3.3')2.5 m (8.2')4.6 m (15.1')8 m (26.2')15.3 m (50.2')23 m (75.5')30.5 m (100.1')11-conductorcable,24 AWG/0.20 mm²RD-styleremovabledisconnect fittingat each end,for cascadeconnectionsbetween SLPC..sensorsRD to Female M12/Euro QD and Mating CordsetsUsed to connect E-stop or other devices to sensor input RDconnection. See Figure 7-8.Model Length Wire TerminationDELPEF-81DDELPEF-83DDELPEF-88DDELPEF-815D0.3 m (1')m )m )m )8-conductorcable,22 AWG/0.33 mm²RD-style fitting atone end, femaleM12/Euro QDfitting at the otherto connect toQDE2R4-8..Dcordset belowQDE2R4-815DQDE2R4-825DQDE2R4-850D4.6 m (15')7.6 m (25')15.2 m (50')8-pinconnector,4-conductorcable,22 AWG/0.33 mm²Male M12/Euro QDfitting at one end,flying leads at theother to enable4-wire hookup todeviceFigure 2-3. EZ-SCREEN LP connection options300 mm 8-pin M12/Euro Pigtail QDOrder mating M12/Euro QD cordsetseparately: QDE, DEE2R, or CSB (seepage 10)RD to RDRequires DELP cordset to connect 2nd,3rd, and 4th sensors in a cascade (seeFigure 7.8 for other options)Integral Removable Disconnect (RD)Requires RDLP, DELPE, orDELPEF cordset (for cascading)Cordset sold separately.Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com