ActiveInactiveTrackMaxTrackMin(t)InputSignalHoldMeasurement HoldMeasurementREMOTEINPUTMeasuring Period Measuring Period(Active Low shown)Figure 27. Track Maximum and Track Minimum3.9 Display Menu (DISPLAY)Use this menu to view or changethe:• Display units• Display orientation• Sleep mode settingsMENU DISPLAYororGo Back to Parent MenuSelect Menu ItemPress to Save SettingPress and Hold to Go Backto Run ModeDISPLAY SleepDISPLAY UnitsSleep 1minSleep DisabledUnits inUnits mmDISPLAY ViewView InvertView NormalSleep 5minSleep 15minSleep 60minDISPLAY Zero Zero NearZero FarDISPLAY Shift Shift OffShift SetZeroShift AutoSetFigure 28. Display Menu Map3.9.1 UnitsThe Units option sets the displayed units to millimeters (mm) or inches (in).Navigate: MENU > DISPLAY > UnitsRemote Input: Not availableDefault: mm3.9.2 Zero and ShiftUse the Display Zero menu to select the zero reference location. The default is , 0 = the face of the sensor.• Near—0 = the face of the sensor; the measurement increases further from the sensor• Far—0 = maximum range; the measurement increases closer to the sensorUse the Display Shift menu to select whether the sensor shifts the zero reference location based on the last TEACHprocess. The default is Off (0).• Off—0 = the face of the sensor or the maximum range, depending on the zero setting• SetZero—Sets the current distance as its new zero reference location. This process is independent of teachinganalog or discrete set points.• AutoSet—Shifts the zero reference location at the taught distance during any analog or discrete setting teach.L-GAGE® LTF Time of Flight Laser Distance Sensor30 www.bannerengineering.com - Tel: +1.763.544.3164