• —Slave sync line output for two-sensor cross-talk avoidanceTo configure sensors for master-slave operation, see Sync Master/Slave on page 22.3.1.7 SensitivityUse this menu to set the sensitivity. The default is standard.• —High sensitivity. Use this setting for low contrast sensing• —Standard sensitivity• —Low sensitivity. Use this setting to stabilize the output in high vibration applications3.1.8 Cut-Off OperationUse this menu to select cut-off operation. The default is• — Output follows LO/DO selection; sensor treats target in background (or loss of signal) as the dark state.• — Output switches OFF when the target is beyond the background suppression distance.• — Output switches ON when the target is beyond the background suppression distance.Table 2: Cut-off output settings and operationOutput State Based on menu and LO/DO SelectionsTarget in Cut-Off No Light Received (Loss of Signal)LO/DO LO/DOOFF LO/DOON LO/DONOTE: The output may transition ON to OFF or OFF to ON when the target enters the diffuse sensingrange. Consider an ON-Delay or the laser inhibit input if necessary.3.1.9 Display ViewUse this menu to select the display view. The default is right-reading.• —Right-reading• —Inverted• —Right-reading and the display enters sleep mode after 60 seconds• —Inverted and the display enters sleep mode after 60 secondsWhen the sensor is in sleep mode, the display wakes with the first button press.3.1.10 Exit the Top MenuNavigate to and press TEACH and MODE together to exit the top menu and return to Run mode.Setup mode can also be exited by pressing and holding and simultaneously for longer than 2 seconds fromanywhere in the top menu.Q3X Laser Contrast Sensor12 www.bannerengineering.com - Tel: 763.544.3164