3.1.11 Reset to Factory DefaultsUse this menu to restore the sensor to the factory default settings. Select to return to the sensor menu withoutrestoring the defaults. Select to restore the sensor to the factory default settings and return to Run mode.Factory Default SettingsSetting Factory DefaultDisplay view ( ) —Right-reading, no sleep modeInput wire function ( ) —Ignore all pulsesOffset Percent ( ) —20%, Window and Light Set—50%, Dark SetOutput operation ( ) —Light operateOutput timing delays ( ) —No delayResponse speed ( ) —1 msSensitivity ( ) —Standard sensitivityTEACH process selection ( ) —Two-point static TEACH3.2 Manual AdjustmentsManually increase or decrease gain using or .1. From Run mode, press either or one time. The current signal strength value flashes slowly.2. Press to decrease the sensor's gain or to increase the sensor's gain, or press and hold or to rapidlydecrease or increase gain. After 1 second, the normalized signal strength flashes rapidly, the new setting isaccepted, and the sensor returns to Run mode.3.3 Remote InputUse the input wire to program the sensor remotely. To program the sensor using the input wire, remote input must beenabled ( = , Input Wire Function on page 11). The remote input provides limited programming options (seeFigure 6 on page 14). Pulse the remote input according to the diagram and the instructions provided in this manual.The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds.Q3X Laser Contrast Sensorwww.bannerengineering.com - Tel: 763.544.3164 13