11ENGLISHGB8. INSTALLATION8.1. Packaging and unpackingDuring unloading and when installing theappliance follow the information from themanufacturer placed directly on the packagingand in this manual.To lift and transport the product plan to use a forklift or stacker, and pay attention to even weightdistribution to avoid a risk of tilting of thepackaging (avoid excessive incline!).While using the elevator payattention to the power cables and gassupply hoses and position of feet.The packaging consists of the carton packagingand wooden pallet. There are symbols printed onthe carton packaging that according to theinternational agreements inform about theregulations to follow when loading and unloading,transporting and storing the appliance.When collecting the goods check if the packagingis complete and has not been damaged duringtransport.Any damage should be immediately reported tothe shipping company.Unpack the appliance as soon as possible tocheck if the appliance is not damaged.Do not use a sharp object to cut the carton box. Itmay damage the stainless steel inside the box.Remove the carton packaging from bottom to top.When unpacked check if the appliance isaccording to the order.In case of any difference inform the sales agentimmediately.Do not store the packagingmaterials (nylon bags, polystyrenefoam, clips ...) in the reach of children!Remove the protective PVC layer from the outand inner surfaces. If possible, do not use anymetal tools.8.2. Installation (service technician)All the stages of the installation must be carefullyplanned.The location should be equipped with all supplyconnections and production waste outlet. Thelocation should also be properly lit and complywith all hygiene and sanitary requirementsaccording to the binding regulations.The appliance should be installed with theminimum 5 cm clearance from the wall, if thewall is not resistant to the minimum temperatureof 150 °C. The devices with the oven must beinstalled at least 50 cm from the wall.Locate the appliance in the horizontal position byadjusting the single feet.To ensure the correct operationof the appliance, the appliance mustbe installed and operated in thethoroughly ventilated room only.50ID 085 cmTHISSIDE UPCAUTIONGLASSKEEP DRY