Physical InterfaceBasler pioneer 1119.7.3 Output Line Response TimeResponse times for the output lines on the camera are as shown below.Fig. 30: Output Line Response TimesTime Delay Rise (TDR) = 1.5 μsRise Time (RT) = 1.3 - 5.0 μsTime Delay Fall (TDF) = 1 - 20 μsFall Time (FT) = 1 - 5 μsNoteThe response times for the output lines on your camera will fall into the rangesspecified above. The exact response time for your specific application willdepend on the external resistor and the applied voltage you use.CameraOutputSignalOutputLineVoltageTimeTDRRTTDF FT90%90%