User Manual - Rev AV AMETEK Programmable PowerMX Series 239The ← key (backspace) will terminate the test at any time.RIPPLEThis test will impose a 400Hz frequency component to the output voltage. The test will last for 2minutes. The level of the ripple is as follows:1. 28V system:±1.5V.2. 270V system:±6.0V.The ← key (backspace) will terminate the test at any time.9.6.1.8.2 Transient TestFrom the MIL704 DC MENU scroll to the TRANSIENT DC entry using the up and down cursorkeys. Press the ENTER key to select the TRANSIENT screen. The screen will appear as shownin Figure 9-40.Figure 9-40: Transient MenuThe Transient Test has the following tests:1 HIGH VOLTAGE2 LOW VOLTAGEHIGH VOLTAGEThis test will change the output voltage for the selected phase in the following sequence:1. 28V System• 50V for 12.5 msec.• Linearly reduce to29V in 70msec.• Stay at 29V for 92.5msec before returning to 28V.2. 270V System• 330V for 20 msec.• Linearly reduce to280V in 20msec.• Stay at 280V for 135msec before returning to 270V.Prior to the test, a range change may take place if the power source is set for the low voltagerange.The ← key (backspace) will terminate the test at any time.Note: A range change will result in momentary loss of power to the EUT. If this is notacceptable, the power source must be left in high range at all times.