Chapter 55-7#DOWNLOADDo not use.#CLEAR (data initialization mode)Various data are initialized by selecting one of these setting items.#ROM (ROM management)ROM data such as the version number and checksum are displayed.The effective SSSWs/parameters and their default values in this machine are shown in Service Data Flowchart. However, detailed descriptions of only service datanewly added to this machine are provided. For descriptions of other service data, which have been used with existing machines, please see the G3 Facsimile SERV-ICE DATA HANDBOOK (Rev. 0), which is supplied separately.5.5.1.3 Service Data Entry Method 0008-1830You can enter the Service Mode with the following operation.F-5-85.5.2 Service Soft Switch Settings (SSSW)5.5.2.1 Outline5.5.2.1.1 Explanation of # SSSW0008-1883The items registered and set by each of these switches comprise 8-bit switches. The figure below shows which numbers are assigned to which bits. Each bit has avalue of either 0 or 1.F-5-9Below are examples showing how to read bit switch tables.F-5-105.5.2.2 SSSW-SW145.5.2.2.1 Details of Bit 0 and Bit 10008-1885Set the type of document scanning size (standard paper) to be used.The following types are set in accordance with the combination of parameters of Bit 0 and Bit1.T-5-4(Bit0, Bit1)= (0, 0) A-series document(0, 1) inch-type document(1, 0) A-series document(1, 1) A-series documentMenu # # SSSWSW01 0 0 0 0 0 0 0 0Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1Bit 0Service error codeNot usedNot usedNot usedNot usedNot usedNot usedNot usedOutput-------Function01234567Bit 1 0Indicates that thesetting is "1".Indicates thedefault settings.Indicates that thesetting is "0".Not Output*-------