2–11STANDARDS AND ADJUSTMENTS19Positioning the Primary Charging Roller Cleaning SolenoidLoosen the two screws used to fix the solenoidein place, and move the solenoid in the direction of thearrow B so that the l in Figure 2-227 is 5.5 ±0.2 mm when the jointqis forced against theasection of thesolenoid support platew.Caution:You must make this adjustment whenever you have replaced the solenoid.Figure 2-227a= 5.5±0.2213B