6-2○ ○ ○ ○ ○ ○VB-C10R Connection ExampleConnector Attached CableIN + , IN – Sensors mounted on the doorUsing the Still Picture Recording Function Linked to an External DeviceEthernetSensor A VB-C10R Camera controland video imagesSensor BBy combining various sensors and switches to operate according to External Device Input settings,it is possible to build a monitoring system that responds to external events. Still pictures arerecorded in the VB-C10/VB-C10R’s memory (→ P.3-16).Sample Application Combining a Door-opening SensorThis is a monitoring system in which the VB-C10R installed in the ceiling records pictures everysecond for 3 seconds before the doors opens and 7 seconds after the door opens between 5 p.m.and 6 a.m. The equipment shown in the figure below is connected to the terminals on the rear ofthe VB-C10R at installation.○ ○ ○ ○ ○ ○Installation ExampleWhen the door opens and sensor B mounted on it separates from sensor A, an ON event occursat external device inputs IN + and IN – . In response to this event, the VB-C10R records pictures atthe entrance and stores them.IN – IN +Remove some insulation at the end of the cables from the sensor andinsert them into the IN + and IN – terminals on the plug for the externaldevice. Then tighten the screws on the plug to secure the cables.Insert this plug with the cable into the external device I/O jack on the rear of the VB-C10R.NotePlease confirm the Date and Time settings on page 3-10.