Chapter 66-142) Multi sensorCheck for normal operation. If the operation is abnormal, replace it.3) Replace the main controller PCB6.1.4 Troubleshooting When Service Call Errors Occur6.1.4.1 E141-4046 Recovery system's count error 0013-7243iPF9000The machine detected that the rotation count of the purge unit reached the specified value.Purge unit or main controller PCB1) Replace the purge unit.After replacing the purge unit, select [SERVICE MODE]>[INITIALIZE]>[PARTS COUNTER] to reset the counter.2) Replace the main controller PCB.6.1.4.2 E144-4047 Supply system's count error 0013-8111iPF9000The machine detected that the carriage scan count reached the specified value.Ink tube unit, or main controller PCB1) Replace the ink tube unit.After replacing the ink tube unit, select [SERVICE MODE] > [INITIALIZE] > [PARTS COUNTER] to reset the counter.2) Replace the main controller PCB.6.1.4.3 E146-4001 Waste ink count full 0013-8106iPF9000The machine detected that the waste ink box or the fan unit became full of ink.Waste ink box, fan unit, or main controller PCB1) Replace the waste ink box or fan unit.After replacing the waste ink box or fan unit, select [SERVICE MODE] > [INITIALIZE] > [PARTS COUNTER] to reset the counter.2) Replace the main controller PCB.6.1.4.4 E161-403E/E161-403F Abnormally high head temperature 0013-7244iPF9000The printhead temperature became abnormally high.Printhead, head relay PCB, carriage relay PCB, or main controller PCB1) Start up the printer in the service mode, and then replace the printhead.2) Replace the head relay PCB.3) Replace the carriage relay PCB.4) Replace the main controller PCB.6.1.4.5 E194-404A Non-discharge detection count error 0013-7253iPF9000The machine detected that the non-discharge count reached the specified value.Head management sensor or main controller PCB1) Replace the head management sensor.After replacing the head management sensor, select [SERVICE MODE] > [INITIALIZE] > [PARTS COUNTER] to reset the counter.2) Replace the main controller PCB. PreviousNext |