Chapter 77-44b) I/O DISPLAYThe information of each sensor and switch is shown in the display.Sensor and switch status is shown in the display.ON=1 OFF or not used=0ON = 1OFF or not used = 0Screen 1T-7-81Screen 2T-7-82Screens 1 and 2 are selectable with the [ ] and [ ] buttons.These screens display the associated sensor status as listed in the table below.T-7-83I / O D I S P L A Y 1 Upper row0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Lower row1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 (Display position)I / O D I S P L A Y 2 Upper row0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Lower row17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 (Display position)Displayposition Sensor name LCD display contents1 Pump Cam Sensor 0: Sensor ON , 1: Sensor OFF2 Valve open/closed detection sensor (R) 0: Sensor ON , 1: Sensor OFF3 Agitation cam sensor (L) 0: Sensor ON , 1: Sensor OFF4 Agitation cam sensor (R) 0: Sensor ON , 1: Sensor OFF5 (Not Used) -6 Lift cam sensor 0: Sensor ON , 1: Sensor OFF7 Feed roller HP sensor 0: Sensor ON , 1: Sensor OFF8 Upper cover lock switch 0: Cover open , 1: Cover close9 Carriage cover sensor 0: Cover open , 1: Cover close10 Ink tank cover switch (R) 0: Cover open , 1: Cover close11 Ink tank cover switch (L) 0: Cover open , 1: Cover close12 (Not Used) -13 (Not Used) -14 (Not Used) -15 (Not Used) -16 (Not Used) -17 (Not Used) -18 (Not Used) -19 (Not Used) -20 (Not Used) -21 (Not Used) -22 Carriage HP sensor 0: Sensor ON , 1: Sensor OFF23 Pressure release switch 0: Realeased , 1:Pressured24 Media sensor 0: No media , 1: Media loaded25 (Not Used) -26 (Not Used) -27 (Not Used) -28 Media take-up unit detection 0: Undetected 1: Detected29 Media take-up sensor input signal 0: LO , 1: HI30 Valve open/closed detection sensor (L) 0: Sensor ON , 1: Sensor OFF31 (Not Used) -32 (Not Used) -