Chapter 1616-32FIX-TEMP Switching the plain paper down sequence table10: OFF (Default)1: Prioritize productivity. Set the control temperature at -20 deg C across the board.2: Set the control temperature at -10 deg C across the board.3: It is -20Åé only in case of 21Åé or more in room temperature as for the controltemperature.4: It is -10Åé only in case of 21Åé or more in room temperature as for the controltemperature.5: Set the control temperature at +6 deg C across the board.6: Set the control temperature at +10 deg C across the board.7: Set the control temperature at +15 deg C across the board.(For DCON Ver.15 or later)This can be set with TEMP-COM or TEMPCON2.Example)When FIX-TEMP is set to -6 deg C and TEMP-COM is set to -6 deg C , the controltemperature is offset by -12 deg C .TRANS-SW Switching transfer high-voltage control from constant current control to constantvoltage control 10: No switching [Default], 1: Constant voltage mode 1, 2: Constant voltage mode 2TEMP-CON Switching the thick paper fixing temperature mode10: OFF (Default)1: Prioritize productivity. Set the control temperature at -10 deg C across the board.2: Set the control temperature at -6 deg C across the board.3: Set the control temperature at -3 deg C across the board.4: Prioritize fixing performance. Set the control temperature at +3 deg C across theboard.5: Set the control temperature at +6 deg C across the board.6: Set the control temperature at +10 deg C across the board.7: Set the control temperature at +15 deg C across the board.This can be set with FIX-TEMP.When FIX-TEMP is set to -6 deg C and TEMP-COM is set to -6 deg C, the controltemperature is offset by -12 deg C.PRIAC-SW Improving the image quality in case of a drum charging faultNote: This setting is cleared if APVC is executed with a new drum unit or if aservice mode (FUNCTION>D-GAMMA) is executed. 10: No UP [Default], 1: 50 mA UP, 2: 100 mA UPTEMPCON2Improving fixing (Increasing the fixing temperature)Switching the multiple plain paper fixing temperature modeThis is only valid for iR3530/3570/3570F/4530/4570/4570F.10: OFF (Default)1: Prioritize productivity. Set the control temperature at -10 deg C across the board.2: Set the control temperature at -6 deg C across the board.3: Set the control temperature at -3 deg C across the board.4: Prioritize fixing performance. Set the control temperature at +3 deg C across theboard.5: Set the control temperature at +6 deg C across the board.6: Set the control temperature at +10 deg C across the board.7: Set the control temperature at +15 deg C across the board.This can be set with FIX-TEMP.When FIX-TEMP is set to -6 deg C and TEMPCOM2 is set to -6 deg C, the controltemperature is offset by -12 deg C.CONFIG Selecting several types of firmware installed on the hard disk and switching thecountry, language, and paper size type of this machine1XXYYZZAAXX: Country (UP), YY: Language (ja), ZZ(00) Destination, AA(00):Paper size typeThe display contents conform to the display method of(COPIER>DISPLAY>USER>LANGUAGE). Enclosed in the brackets aredefaults. The country and language are only displayed.1) Select .2) Select an item to reverse its display. Then press the + or - key to change thecontents.3) Each time the + or - key is pressed, the contents change sequentially.4) Display the intended contents at all items and press the OK key.5) Turn the main power switch OFF and ON.W/SCNR Setting whether a scanner is present (Copy model) 10: Printer model [Default]1: Model with scannerCOPIER > OPTION > BODYSub-item Description Level PreviousNext |