CarNetix CNX-P1290 V1.0 Installation Manual7.2.7 Forced Shutdown StateIf the SSC detects either 1) a low battery (<10.5volts for >10seconds), 2) a fan fault, or 3) an OverCurrent condition, the SSC enters a Forced Shutdown state. During this state the SSC immediatelybegins a Shutdown Sequence without first entering the Shutdown Delay State. The ShutdownSequence cannot be exited by turning on (or leaving on) the ignition. After a Forced Shutdown Stateis completed, the ignition switch must be turned off to unlock the state and re-start the CarPC.7.3 Fault Indicator LEDSThe CNX-P1290 has 2 LEDs that give an indication of the status and states of the SSC. The patternand blink-rates of these LED have different meanings depending upon what state the SSC is in.Below is a link to the LED codes.- 38 -