Owner’s Manual | Model A704-5 Aviation Lighting System23© 2008 Carmanah Technologies CorporationLast revised: April 2008To cancel Emergency Mode: Press EMERG/ALL (Clears the EMERG LED) Press ENTER (The previously selected groups become active)5.6.10 ClearPressing CLEAR deselects all buttons pressed since ENTER was last pressed.Turn controller off.5.7 Advanced User OperationsThis section outlines the advanced user operations of the wireless controller.5.7.1 Battery Diagnose FunctionThe Diagnose function sends a command to the lights to display the charge level of the batteries.Lights within the following battery charge ranges will identify themselves by responding with five (5)flashes. The light must be steady-on state for the flashes to be visible: DIAGNOSE, HIGH: 75% to 100% DIAGNOSE, MED: 50% to 75% DIAGNOSE, LOW: 5% to 50% (not including Low Battery State) DIAGNOSE, Lights Off: Low Battery State (5% or less)To enter Diagnose Mode on the controller: Press DIAGNOSE (The DIAGNOSE LED starts flashing) Press ENTER (The DIAGNOSE LED turns on)To send the Diagnose command to the lights: Press (one of) HIGH, MED, LOW or Lights Off. Press ENTERTo exit diagnose mode on the controller: Press DIAGNOSE (The DIAGNOSE LED starts flashing) Press ENTER (The DIAGNOSE LED turns off)5.7.2 Radio Health Diagnose FunctionThe Radio Health Diagnose function sends a command to the lights to display a radio health indication.The A704-5 light continually monitors the health of its radio module and automatically restarts the radio ifneeded. A count is kept of these restart events; intermittent radio problems are thus automaticallyrecovered from and are very likely to go unnoticed in normal operation. For chronic radio health issues,the A704-5 light will automatically flash five times every minute.To enter Diagnose Mode on the controller: Press DIAGNOSE (The DIAGNOSE LED starts flashing) Press ENTER (The DIAGNOSE LED is on)To send the Radio Health Diagnose command to the lights: Press EMERG/ALL Press ENTER