SECTION 33-33 T-268-07Table 3-10. DataCORDER Pre-Trip DataTEST # TITLE DATANOTE“Auto” or “Auto1” menu includes the following: P, P1, P2, P3, P4, P5, P6 and rSLts. “Auto2’ (Optional)menu includes the following: P, P1, P2, P3, P4, P5, P6,P7, P8, P9, P10 and rSLts. (Refer to section 3.2.1.)1-0 Heater On Pass/Fail/Skip Result, Change in current for Phase A, B and C1-1 Heater Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C2-0 Condenser Fan On Pass/Fail/Skip Result, Water pressure switch (WPS) -- Open/Closed,Change in currents for Phase A, B and C2-1 Condenser Fan Off Pass/Fail/Skip Result, Change in currents for Phase A, B and C3-0 Low Speed Evaporator FanOnPass/Fail/Skip Result, Change in currents for Phase A, B and C3-1 Low Speed Evaporator FanOnPass/Fail/Skip Result, Change in currents for Phase A, B and C4-0 High Speed Evaporator FanOnPass/Fail/Skip Result, Change in currents for Phase A, B and C4-1 High Speed Evaporator FanOnPass/Fail/Skip Result, Change in currents for Phase A, B and C5-0 Supply/Return Probe Test Pass/Fail/Skip Result, STS, RTS, SRS and RRS5-1 Secondary Supply Probe Test Pass/Fail/Skip Result5-2 Secondary Return Probe Test Pass/Fail/Skip Result6-0 Compressor On -- High Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C6-1 Compressor On -- Low Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C6-2 Suction Modulation ValveOpenPass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?6-4 Suction Modulation ValveClosedPass/Fail/Skip Result, STS, RTS, Delta T1, Delta T2,Is current limit in effect? (Y,N)?6-5 Suction Solenoid Valve Open Pass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?7-0 High Pressure Switch Closed Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)Input values that component opens?7-1 High Pressure Switch Open Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)Input values that component closes?8-0 Perishable Heat Pass/Fail/Skip Result, STS, time it takes to heat to 16_C (60_F)?8-1 Perishable Pull Down Pass/Fail/Skip Result, STS, time it takes to pull down to 0_C (32_F)?8-2 Perishable Maintain Pass/Fail/Skip Result, Averaged DataCORDER supply temperature(SRS) over last recording interval.9-0 Defrost Test Pass/Fail/Skip Result, DTS temperature at end of test, line voltage,line frequency, time in defrost.10-0 Frozen Mode Set-up Pass/Fail/Skip Result, STS, time unit is in heat.10-1 Frozen Mode Pull Down Pass/Fail/Skip Result, STS, time to pull down unit to --17.8_C (0_F).10-2 Frozen Mode Maintain Pass/Fail/Skip Result, Averaged DataCORDER return temperature(RRS) over last recording interval.