3–9 T-3653.5 REFRIGERATION CIRCUIT3.5.1 Standard OperationStarting at the compressor, (see Figure 3.6, upper schematic) the suction gas is compressed to a higher pressureand temperature.The refrigerant gas flows through the discharge line and continues into the air-cooled condenser. When operatingwith the air-cooled condenser active, air flowing across the coil fins and tubes cools the gas to saturation tempera-ture. By removing latent heat, the gas condenses to a high pressure/high temperature liquid and flows to thereceiver, which stores the additional charge necessary for low temperature operation.The liquid refrigerant continues through the liquid line, the filter drier (which keeps refrigerant clean and dry) andthe economizer (not active during standard operation) to the electronic expansion valve (EEV).As the liquid refrigerant passes through the variable orifice of the EEV, the pressure drops to suction pressure. Inthis process some of the liquid vaporizes to a gas (flash gas), removing heat from the remaining liquid. The liquidexits as a low pressure, low temperature, saturated mix. Heat is then absorbed from the return air by the balance ofthe liquid, causing it to vaporize in the evaporator coil. The vapor then flows through the suction tube back to thecompressor.During the standard mode of operation, the normally closed valves, digital loader valve (DLV) and digital unloadervalve (DUV), control the system refrigerant flow and capacity by loading and unloading the compressor in frequentdiscrete time intervals. The DLV and DUV operate in opposition to each other such that when the DLV is closed theDUV is open and vice versa. The valves cycle on a fixed duty cycle so that maximum capacity occurs when theDLV is open 100% of the time and the DUV is open 0% and minimum capacity is when the DLV is open 0% of thetime and the DUV 100% of the time. If the system capacity has been decreased to the lowest allowable capacity,the unit will enter a trim heat mode of operation, during which the controller will pulse the evaporator heaters insequence with the compressor digital signal in order to absorb the excess capacity.3.5.2 Economized OperationIn the economized mode, (see Figure 3.7) the frozen and pull down capacity of the unit is increased by sub- cool-ing the liquid refrigerant entering the electronic expansion valve. Overall efficiency is increased because the gasleaving the economizer enters the compressor at a higher pressure, therefore requiring less energy to compress itto the required condensing conditions.Liquid refrigerant for use in the economizer circuit is taken from the main liquid line as it leaves the filter drier. Theflow is activated when the controller energizes the economizer solenoid valve (ESV).The liquid refrigerant flows through the ESV to the economizer expansion valve internal passages, absorbing heatfrom the liquid refrigerant flowing to the electronic expansion valve. The resultant “medium” temperature/pressuregas enters the compressor at the economizer port fitting.3.5.3 Economizer Expansion ValveThe microprocessor controls the superheat leaving the economizer expansion valve (EXV). From the EXV therefrigerant flows through the internal passages of the economizer heat exchanger, absorbing heat from the refriger-ant flowing to the EEV. The resultant “medium” temperature/pressure gas enters the compressor at the economizerport fitting.Abnormal pressures/temperatures inthe high refrigerant sideFusible Plug - Used on the Receiver 99°C = (210°F)Rupture Disc - Used on the Water-Cooled Condenser 35 kg/cm 2 = (500 psig)Abnormally high discharge pressure High Pressure Switch (HPS) Opens at 25 kg/cm 2 (350 psig)Table 3–2 Safety and Protective Devices (Continued)UNSAFE CONDITION DEVICE DEVICE SETTING