4–19 T-3659. Evaporator expansion valve percentage10.Discrete outputs (Bit mapped - require special handling if used)11. Discrete inputs (Bit mapped - require special handling if used)12.Ambient temperature sensor (AMBS)13.Evaporator temperature sensor (ETS)14.Compressor discharge sensor (CPDS)15.Return temperature sensor (RTS)16.Supply temperature sensor (STS)17.Defrost temperature sensor (DTS)18.Discharge pressure transducer (DPT)19.Suction pressure transducer (SPT)20.Flash tank pressure transducer (FPT)21.Vent position sensor (VPS)- - - - -4.8.4 Logging Interval (dCF03)The user may select four different time intervals between data recordings. Data is logged at exact intervals inaccordance with the real time clock. The clock is factory set at Greenwich Mean Time (GMT).4.8.5 Thermistor Format (dCF04)The user may configure the format in which thermistor readings are recorded. The short resolution is a 1 byte for-mat and the long resolution is a 2 byte format. The short requires less memory and records temperature with vari-able resolutions depending on temperature range. The long records temperature in 0.01°C (0.02°F) steps for theentire range.CONFIGURATION NO. TITLE DEFAULT OPTIONdCF01 (Future Use) -- --dCF02 Sensor Configuration 2 2,5,6,9,54,64,94dCF03 Logging Interval (Minutes) 60 15,30,60,120dCF04 Thermistor Format Short LongdCF05 Thermistor Sampling Type A A,b,CdCF06 Controlled Atmosphere/Humidity Sampling Type A A,bdCF07 Alarm Configuration USDA Sensor 1 A Auto, On, OffdCF08 Alarm Configuration USDA Sensor 2 A Auto, On, OffdCF09 Alarm Configuration USDA Sensor 3 A Auto, On, OffdCF10 Alarm Configuration Cargo Sensor A A Auto, On, Off