4MODEL NUMBER NOMENCLATURECoil Options For Round Tube/Plate Fin Condenser Coil Models Only (outdoor-indoor-hailguard)A = Al/Cu - Al/CuB = Precoat Al/Cu - Al/CuC = E-coat Al/Cu - Al/CuD = E-coat Al/Cu - E-coat Al/CuE = Cu/Cu - Al/CuF = Cu/Cu - Cu/CuM = Al/Cu - Al/Cu – Louvered Hail GuardsN = Precoat Al/Cu - Al/Cu – Louvered Hail GuardsP = E-coat Al/Cu - Al/Cu – Louvered Hail GuardsQ = E-coat Al/Cu - E-coat Al/Cu – Louvered Hail GuardsR = Cu/Cu - Al/Cu – Louvered Hail GuardsS = Cu/Cu - Cu/Cu – Louvered Hail GuardsCoil Options For All Aluminum – Novation Condenser Coil Models Only(outdoor-indoor-hailguard)G = Al/Al – Al/CuH = Al/Al – Cu/CuJ = Al/Al – E-coat Al/CuK = E-coat Al/Al – Al/CuL = E-coat Al/Al – E-coat Al/CuT = Al/Al – Al/Cu, Louvered Hail GuardsU = Al/Al – Cu/Cu, Louvered Hail GuardsV = Al/Al – E-coat Al/Cu, Louvered Hail GuardsW = E-coat Al/Al – Al/Cu, Louvered Hail GuardsX = E-coat Al/Al – E-coat Al/Cu, Louvered Hail Guards4 8 T C D A 0 4 A 1 A 5 - 0 A 0 A 0Unit Heat Type48 – Gas HeatPackagedRooftopSeries/ModelTC – Standard EfficiencyHeat SizeD – Low heatE – Medium HeatF – High HeatL – Low NOx , Low HeatM – Low NO x, Medium HeatN – Low NOx , High HeatS – Stainless Steel, Low HeatR – Stainless Steel, Medium HeatT – Stainless Steel, High HeatRefrig. Systems OptionsA - Standard One Stage Cooling ModelsB – Standard One Stage Cooling Modelswith Humidi-MiZer (04-07 models only)D – Two Stage Cooling Models 08-16E – Two Stage Cooling Models 08-16with Al/Cu condenser Coils andwith Humidi-MiZerCooling Tons04 - 3 ton 08 – 7.5 ton 16 – 15 Tons05 - 4 ton 09 – 8.5 ton06 - 5 ton 12 – 10 ton07 - 6 ton 14 – 12.5 tonPackaging and Seismic Compliant0 = Standard1 = LTL3 = CA Seismic Compliant4 = LTL and CA Seismic Compliant LabelElectrical OptionsA = NoneC = Non-Fused DisconnectD = Thru-The-Base ConnectionsF = Non-Fused Disconnect and Thru-The-Base ConnectionsG = 2-Speed Indoor Fan (VFD) ControllerJ = 2 Speed Fan Controller (VFD) and Non-Fused DisconnectK = 2 Speed Fan Controller (VFD) and Thru-The Base ConnectionsM = 2 Speed Fan Controller (VFD) with Non-Fused Disconnect andThru-The Base ConnectionsService Options0 = None1 = Unpowered Convenience Outlet2 = Powered Convenience Outlet3 = Hinged Panels4 = Hinged Panels, Unpowered Convenience Outlet5 = Hinged Panels, Powered Convenience OutletIntake / Exhaust OptionsA = NoneB = Temperature Economizer w/ Barometric ReliefF = Enthalpy Economizer w/ Barometric ReliefK = 2-Position DamperU = Temp Ultra Low Leak Economizer w/Baro ReliefW = Enthalpy Ultra Low Leak Econo w/Baro ReliefBase unit controls0 = Electro Mechanical controls. Can be used with W7212 EconoMi$er IV(Non-Fault Detection and Diagnostic)1 = PremierLink Controller2 = RTU Open Multi-Protocol Controller6 = Electro Mechanical controls. Can be used with W7220 EconoMi$er X(with Fault Detection and Diagnostic)Sensor OptionsA = NoneB = RA Smoke DetectorC = SA Smoke DetectorD = RA + SA Smoke DetectorE = CO2 SensorF = RA Smoke Detector and CO2 SensorG = SA Smoke Detector and CO2 SensorH = RA + SA Smoke Detector and CO2 SensorIndoor Fan Options1 = Standard Static Option2 = Medium Static Option3 = High Static OptionC = High Static Option w/ High Effy Motor (Size 16 Only)Design RevisionFactory AssignedVoltage1 = 575/3/60 5 = 208-230/3/603 = 208-230/1/60 6 = 460/3/601 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18Note: On single phase (-3 voltage code) models, the followingare not available as a factory installed option:- Humidi-Mizer- Coated Coils or Cu Fin Coils- Louvered Hail Guards- Economizer or 2 Position Damper- Powered 115 Volt Convenience OutletNot all possible options can be displayed above.C13211B