5Table 1 – FACTORY--INSTALLED OPTIONS AND FIELD--INSTALLED ACCESSORIESCATEGORY ITEMFACTORYINSTALLEDOPTIONFIELDINSTALLEDACCESSORYCabinetThru ---the---base electrical or gas---line connections X XSupply Duct Cover (16 size only) XCalifornia Seismic Compliant Labeling XHinged Access Panels XCoil OptionsCu/Cu indoor and/or outdoor coils1, 6 XPre---coated outdoor coils1, 6 XPremium, E ---coated outdoor coils1, 6 XHumidity Control Humidi ---MiZer Adaptive Dehumidification System 6 XCondenser Protection Condenser coil hail guard (louvered design)6 X XControlsThermostats, temperature sensors, and subbases XPremierLink DDC communicating controller X XRTU Open ---protocol controller XSmoke detector (supply and/or return air) XTime Guard II compressor delay control circuit XPhase Monitor XEconomizers& Outdoor AirDampersEconoMi$er IV for electro---mechanical controls --- Non FDD(Standard air leak damper models)6, 7 X XEconoMi$er2 for DDC controls, complies with FDD (Standardand Ultra Low Leak air damper models)6, 8 X XMotorized 2 position outdoor air damper6 X XManual outdoor air damper (25% and 50%) XBarometric relief 2 X XPower exhaust XEconoMi$er X for electro---mechanical controls, complies withFDD. (Standard and Ultra Low Leak air damper models)6, 7 X XEconomizerSensors&IAQ DevicesSingle dry bulb temperature sensors3 X XDifferential dry bulb temperature sensors3 XSingle enthalpy sensors3 X XDifferential enthalpy sensors3 XWall or duct mounted CO 2 sensor3 XUnit mounted CO 2 sensor3 XGas HeatPropane conversion kit XStainless steel heat exchanger XHigh altitude conversion kit XFlue Shield (04---14 sizes only) XFlue Discharge Deflector (04---14 sizes only) XIndoor Motor& DriveMultiple motor and drive packages XStaged Air Vol (SAV) system w/VFD controller (2---stage coolonly with electrical mechanical and RTU Open controls) XDisplay Kit for SAV system with VFD XLow AmbientControlWinter start kit4 XMotormaster head pressure controller4 XPowerOptionsConvenience outlet (powered)6 XConvenience outlet (un ---powered) XNon ---fused disconnect5 XDisconnect Switch Bracket (16 size only) XRoof Curbs Roof curb 14---in (356mm) XRoof curb 24---in (610mm) XNOTES:1. Novation coated coils only available with E--- coat.2. Included with economizer.3. Sensors used to optimize economizer performance.4. See application data for assistance.5. Available on units with MOCP’s of 80 amps or less.6. Not available as factory installed option on single phase (208/230/1/60) models. Use field --- installed accessory where available.7. FDD (Fault Detection and Diagnostic) capability per California Title 24 section 120.2.8. Models with RTU Open DDC controls comply with California Title 24 Fault Detection and Diagnostic (FDD). PremierLink is non FDD.