26InitializationInit 2 operation1. Plug the power cord into an AC outlet.2. Set the mode switch to OFF position.3. While holding down j, set the mode switch to PGM.4. Release j.5. Enter “99990000” and press s to enter the diagnosis.REG2 X1REG1 Z1OFF X2/Z2RFPGM REG2 X1REG1 Z1OFF X2/Z2RFPGMJOURNALFEEDRECEIPTFEEDJOURNALFEEDRECEIPTFEED1. Plug the power code into an AC outlet.2. Set the mode switch to OFF position.3. While holding down f, set the mode switch to PGM.4. Release f.You should see “FFFFFFFFFF” on the display.If 10 Fs are not shown or another character are shown,immediately set the mode switch to OFF and restart fromthe beginning of this procedure.5. Enter “8888888888” and press k to complete.REG2 X1REG1 Z1OFF X2/Z2RFPGM REG2 X1REG1 Z1OFF X2/Z2RFPGMJOURNALFEEDRECEIPTFEEDJOURNALFEEDRECEIPTFEEDAfter completion of flag clear, receipt is issued.Entering diag modePasswordDuring initialize operation, you can program the password for PGM 3 ~ 7. If it is set, every time you enter PGM 3 ~ 7mode, you must input this password by the following procedure.1. Press <#-1> (normally a).2. Enter password.3. Press <#-2> (normally s).Otherwise, you can do nothing in the PGM 3 ~ 7 mode.