17Programmable input 1- Partial Opening Input.The gate can be opened for an adjustable period, e.g. to let through pedestrian traffic. The time ismeasured from the gate leaving the Close limit position for motor 1. With this function, the gate stopsafter it has been opening for the set time. Restricted opening input can be set to open gate leaf 1 only.The gate will then open one leaf for a set time. If required to open one half to the fully open position,the restricted opening time should be set to 0. A "Close" command always closes both leaves.Set time for restricted opening (C60)1. Step to C60 (time setting).2. Set the time for which the gate is to travel open.Set opening of gate leaf 1 only (C61)1. Step to C61 (setting).2. Set 0 if only gate leaf 1 is to open.3. The gate opens after the time set on C60.Programmable input 2 - Open / Stop / Close and further controls.This programmable input has several functions:0=Turned off1=Open/stop/close2=Open only gate leaf 23=Interlock.4=For future use5=Automatic closing turned off6=Open gate+automatic closing turned offDetailed explanations follows below:Open/stop/close (C62=1):If the door is moving and you give one signal to the input the door will stop, if you give one more signalit will change direction. After the door has been still for 5 sec or more the function is always openGate leaf 2 open function (C62=2):When the input is set for gate leaf 2 opening, the input signal always results in opening gate leaf 2.Inter lock function (C62=3)EP102 sends an opening signal to another EP102, for inter lock opening. Communication cable isrequired.Automatic closing turned off (C62=5)Turns off automatic closing as long as there is a signal on this input. Meanwhile you can open andclose the gate with normal open and close signals.Eg. 07.00 there is a signal on input 2 from a clock. When the gate is opened after 07.00 it will remainopen during the day. When the signal disappears automatic closing is activated. When the signal is onit is possible to close the gate during lunch.Open gate and automatic closing turned off (C62=6)The gate opens immediately when there is a signal on input 2. Otherwise same functions as C62=5.