MODELMODEL 2500_______________________________________________________2500________________________________________________________________________________________________________________NOTE! Applications in which report lengths are in excess ofone page require a printer with an 8k buffer capacity,or the baud rate of the printer output signal must belowered to 300, and the RPTGAP lower level sub-menumust be set to SPACES._________________________________________________________TABLESThe TABLES sub-menu, which is the seventh sub-menu on the MAIN MENU, hasa lower level sub-menu for each data table defined in the configuration.TUBE SWITCHINGThe TUBE SWITCHING sub-menu, which is the eighth sub-menu on the MAINMENU, provides the following list of variables that define common switchingparameters for all tube sets and individual switching parameters for each tube ina set.Common switching parameters for all tube sets:Time delay variable The time delay variable is a user-entered intervalthat allows time for a valve to change position, andfor the position change to affect the differentialpressure across the tube set before the position ofthe next valve in the set is changed. The defaultvalue for this variable is 120 seconds.Verify DP variable The verify DP variable enables or disablesautomatic verification of the differential pressure________________________________________________________________________________________________________________________________________SECTIONSECTION 44 49