6Planning the InstallationLocation Planning - GeneralGas and Electric Power RequirementsPrior to installation, the gas supply for natural gas or•whole house LP installations must meet the specifica-tions below.For natural gas or whole house LP installations, have a•qualified plumber or gas fitter install a 3/4 inch (19mm)or 1/2 inch (13mm) gas supply line with a shut-off valve(not included). Have it installed in an accessible loca-tion that allows it to be shut off when the appliance isinstalled.gas supply requirementsModel Type Manifold pressure Minimum gassupply pressureNatural Gas 4” Water Column 5” Water ColumnLP Gas 11” Water Column 12” Water ColumnCorrect voltage, frequency and amperage must be sup-•plied to the appliance from an isolated, grounded circuitwhich is protected by a properly sized circuit breaker ortime-delay fuse. The required voltage, frequency, andamperage ratings are listed on the product data plateand are also below.electrical requirementsCircuit Requirement 120 Vac, 15 Amp.Total Connected Load 2.9 Amps, (0.35 kW)It is the owner’s responsibility to ensure that the elec-•trical connection to this appliance is installed by aqualified electrician. The electrical installation, includ-ing minimum supply wire size and grounding, must bedone in accordance with National Electric Code ANSI/NPFA 70, (or the latest revision) or Canadian ElectricalCode CSA C22.1, and local codes and ordinances forconnection of an outdoor appliance.Locate the electrical outlet within reach of the 48 Inch•(1219mm) long power cord so that it will reach whenthe grill is completely installed in the enclosure.Total connected loads shown include the ignition sys-•tem, interior lights and rotisserie motor.The rotisserie motor should be plugged into the same•grounded outlet power source or an alternate 120 Vacduplex outlet located on the same circuit as the grill.warningThis installation must conform to local codes or, in the•absence of local codes, with either the National FuelGas Code, ANSI Z223.1/NFPA 54, Natural Gas andPropane Installation Code, CSA B149.1, or PropaneStorage and Handling Code, B149.2.Prevent grill combustion products from being drawn•into a building through fresh air inlets: The ventingsystem of other than a direct-vent appliance mustterminate at least 4 feet (1.2m) below, 4 feet (1.2m)horizontally from, or 1 foot (305mm) above any door,window or gravity air inlet into any building. The bot-tom of the vent terminal must be located at least 12inches (305mm) above grade.A MINIMUM clearance of 10 inches (254mm) must be•maintained, above the countertop material, from allcombustible vertical materials on the sides and behindthe outdoor grill chassis and canopy.On all models except OBSB162, a MINIMUM clear-•ance of 1 1/4 inches (32mm) must be maintained,above the countertop material, from all non-combus-tible vertical materials on the sides and behind theoutdoor grill chassis and canopy.On model OBSB162, a MINIMUM clearance of 2 inch-•es (51mm) must be maintained, above the countertopmaterial, from all non-combustible vertical materialson the sides and behind the chassis.A MINIMUM clearance of 1/4 inch (6mm) must be•maintained, inside the base enclosure below thecountertop material, from all vertical surfaces on thesides of the appliance, except on model OBSB162.On model OBSB162 a minimum clearance of 1/4 inch(6mm) must be maintained in back and 1/16 inch onthe sides.A MINIMUM clearance of 3/4 inch (19mm) must be•maintained, from the bottom of the control panel toany material for ventilation purposes. Failure to do sowill block air flow through the outdoor grill and maycause carbon monoxide poisoning or improper opera-tion.The back edge of the grill must maintain a minimum•clearance (10 inches/254mm) from combustible backsplash materials. Special cabinet and countertopdimensions are required.The electrical outlet and gas service must be installed•only by a qualified, licensed professionals.The maximum gas supply pressure to the regulator•must not exceed 1/2 pound per square inch.Use only the factory supplied gas regulator or a Dacor•approved replacement.