SiBE12-908 CheckService Diagnosis 1703.3 Installation Condition CheckCheck No.033.4 Outdoor Fan System Check (DC Motor)Check No.05Check No.23Refer to P.177(R9459)Installation condition checkChange the position of the airdischarge grille or theinstallation location.NOYESYESNOYESNONormalAbnormalCheck the allowabledimensions of the airsuction and dischargearea.Does thedischarged air fromother outdoor unitcause an increaseof the suction airtemperature?Is the heatexchanger verydirty?Is the airflow blocked byobstacles or windsblowing in the oppositedirection?Change the position of the airdischarge grille or theinstallation location.Clean the heat exchanger.Change the installationlocation or direction.Check the outside airtemperature (temperature of airtaken in by the outdoor unit).(The outside air temperatureshall be 46°C or lower.)(R9460)Outdoor fan system checkRectify.YESNO NOYESDoes the outdoor fanrotate?Check the fan motorlead wire connector forsecure connectionThe outdoor fan system is OK To Check No.23