Main Functions SiBE12-90835 Function and Control1.14 Table for Special ModesA. Forced operation mode:The buzzer beeps, and the timer and multi-colored indicator lamp illuminate.Refer to page 53 for detail.B. Easy diagnosis mode:You can identify the error code in a quite simple way but some of the error codes do not appearon the LCD.Refer to the Check Method 1 on page 104 for detail.1. Service check mode:You can identify the error code for diagnosis.Refer to the Check Method 2 on page 105 for detail.(R9416)Indoor [ON/OFF] 5~9 sec.[CANCEL] 5 sec.A Forced operation modeB Easy diagnosis mode• Indoor [ON/OFF]• Left for 15 min.• [CANCEL] 5 sec.• Left for 60 sec.Left for 60 sec.Mode selection view:Select with TEMP or button.[MODE]+TEMP+TEMP Service check modeTrial operation modePipe set modePipe check modeDrying modeHumiditying airflowrate setting modeMonitor brightnesssetting mode12345675CTP5PCHL[MODE][MODE][MODE][MODE][MODE][MODE][MODE]DiagnosisTrial operation ONHose length settingHose length checkHose Dryoperation ONAirflow ratesettingMonitor brightnesssetting[MODE] 2 sec.• [MODE] 5 sec.• Left for 60 sec.• Operation OFF• Left for 30 min.• [MODE] 5 sec.• Left for 60 sec.• [MODE] 5 sec.• Left for 30 min.• [MODE] 5 sec.• Left for 60 sec.• [MODE] 5 sec.• Left for 60 sec.Normal modeNormal mode