Outdoor Unit SiBE12-908227 Removal Procedure2.6 Removal of Hygroscopic Fan Rotor / Hygroscopic Fan MotorProcedure Warning Be sure to wait 10 minutes or more after turning off all power suppliesbefore disassembling work.Step Procedure Points1. Removal of thehygroscopic fan rotorASSYPreparation Remove the humidifyingrotor according to "Removalof Humidifying Rotor".1 Disconnect theconnector for fan motorand remove the bellmouth on adsorptionside.2 Unscrew the fan fixingnut (M6) of thehygroscopic fan rotorASSY (sirocco fan rotorASSY) and remove. When reassembling, alignthe mark and D cut of themotor shaft. Spanner size: 10mm2. Removal of thehygroscopic fan motor Lift the motor cover first andpull out.1 Remove the 3 screwsof the motor cover.2 Remove thehygroscopic fan motor.(R9928)Fan fixingnut Hygroscopicfan rotorASSYHygroscopicfan motorMotor cover