Field Setting from Remote Controller SiME281501E51 Field Setting2. Field Setting from Remote ControllerIndividual function of indoor unit can be changed from the remote controller. At the time of installation or afterservice inspection / repair, make the field setting in accordance with the following description.Wrong setting may cause error.(When optional accessory is mounted on the indoor unit, setting for the indoor unit may be required tochange. Refer to information in the option handbook.)2.1 Wired Remote Controller2.1.1 BRC1C61/BRC1D611. When in the normal mode, press the “ ” button for 4 seconds or more, and the FIELD SETTINGMODE is entered.2. Select the desired MODE NO. with the “ ” button (2).3. During group control, when setting by each indoor unit (mode No. 20, 22 and 23 have been selected),press the “ ” button (3) and select the INDOOR UNIT NO to be set. (This operation is unnecessarywhen setting by group.)4. Press the “ ” upper button (4) and select FIRST CODE NO.5. Press the “ ” lower button (5) and select the SECOND CODE NO.6. Press the “ ” button (6) once and the present settings are SET.7. Press the “ ” button (7) to return to the NORMAL MODE.(Example)If during group setting and the time to clean air filter is set to FILTER CONTAMINATION, HEAVY, SETMODE NO. to “10” FIRST CODE NO. to “0”, and SECOND CODE NO. to “02”.3 456712UNIT NO.SECONDCODE NO.FIRSTCODE NO.MODE NO.FIELDSETTINGMODETESTTEST