Falcon 4M Camera ManualDALSA 03-032-20044-01152.2 Input/Output Connectors and LEDThe camera uses:• A diagnostic LED for monitoring the camera. See LED Status Indicator in section 2.2.1LED Status Indicator for details.• Two high-density 26-pin MDR26 connectors for Camera Link control signals, datasignals, and serial communications. Refer to section 2.2.2 Camera Link• Data Connector for details.• One 6-pin Hirose connector for power. Refer to section 2.2.3 Power Connector fordetails.Figure 6: Input and OutputCamera Link (Base Configuration)Camera Link (Medium Configuration)Diagnostic LED+12V to +15VCONTROLDATA 1DATA 2POWERWARNING: Ensure that all the correct voltages at full load are present at the camera end of thepower (irrespective of cable length) according to the pinout defined in section 2.2.3 PowerConnector.2.2.1 LED Status IndicatorThe camera is equipped with a red/green LED used to display the operational status ofthe camera. The table below summarizes the operating states of the camera and thecorresponding LED states.When more than one condition is active, the LED indicates the condition with the highestpriority. Error and warning states are accompanied by corresponding messages furtherdescribing the current camera status.Status LEDColor of Status LED MeaningFlashing Green Camera initialization or executing a time consuming commandSolid Green Camera is operational and functioning correctlyFlashing Red Fatal Error. System voltage out of tolerance.Solid Red Warning. Loss of functionality (e.g. external SRAM failure)