Falcon 4M Camera Manual03-032-20044-01 DALSA74Appendix BError Handling andCommand ListB1 All Available CommandsAs a quick reference, the following table lists all of the commands available to the camerauser. For detailed information on using these commands, refer to Chapter 3.All Available CommandsCommand Syntax Parameters Descriptioncorrection calibrateFPNccf Performs FPN calibration andeliminates FPN noise by subtractingaway individual pixel dark current.camera link mode clm m Output mode to use:2: Base configuration, 2 taps, 8 bitoutput3: Base configuration, 2 taps, 10 bitoutput15: Medium configuration, 4 taps, 8 bitoutput (4M60 only)16: Medium configuration, 4 taps, 10bit output (4M60 only)calculate PRNUalgorithmcpa i i Performs PRNU calibration accordingto the selected algorithm.The first parameter is the algorithmwhere i is:2 = Calculates the PRNU coefficientsusing the entered target valuePRNU Coefficient = Target(AVG Pixel Value ) ‐ (FPN + value)sdoi iiThis algorithm is useful for achievinguniform output across multiplecameras.Parameters:t = tap idi = integer valuef = real numbers = stringm = member of aset