Falcon 4M Camera ManualDALSA 03-032-20044-0121s = stringt = tap idx = pixel column numbery = pixel row numberExample: to retrieve the current camera settingsgcp Setting Baud RatePurpose: Sets the speed in bps of the serial communication port.Syntax: sbr mSyntax Elements: mBaud rate. Available baud rates are: 9600 (Default), 19200,57600, and 115200.Notes: • Power-on rate is always 9600 baud.• The rc (reset camera) command will not reset the camera tothe power-on baud rate and will reboot using the last usedbaud rate.Example: sbr 57600Camera Help ScreenFor quick help, the camera can retrieve all available commands and parameters throughthe serial interface.To view the help screen, use the command:Syntax: hThe help screen lists all commands available. Parameter ranges displayed are the rangesavailable under the current operating conditions. The ranges depend on the currentcamera operating conditions, and you may not be able to enter these values.Example Help Screen (4M60)ccf correction calculate fpnclm camera link mode m 2/3/15/16/cpa correction prnu algorithm mi 2/4/:1-1023csn coefficient set number i 0-15css correction set sample m 32/64/128/256/512/1024/dpc display pixel coefficients xyxy 1-2352:1-1728:1-2352:1-1728edc enable debounce circuit m 0/1/efd enable frame dump m 0/1/2/epc enable pixel coefficients ii 0-1:0-1gcm get camera modelgcp get camera parametersgcs get camera serialgcv get camera versiongfc get fpn coefficient xy 1-2352:1-1728