54 Operational Reference Genie Monochrome Series-GigE Vision CameraInput Controls via Sapera LT or GigE Vision Compliant ApplicationsSaperaGenie Sapera parameters for Trigger Modes, Time Stamp and General Inputs:TriggerDelayToIntegration = Delay in μs from trigger to exposureTriggerEnable = {FALSE, TRUE}TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2}TriggerSoftware = {FALSE, TRUE}FramesPerTrigger = Frame count 1 to 64kTimestampResetSource = {Off = 0, Input 1 = 1, Input 2 = 2}TimestampCounter = {Internal Clock = 0, Input 1 = 1, Input 2 = 2, End of Readout = 3}TimestampReset = {FALSE, TRUE}PolarityInput_x = {Active High = 0, Active Low = 1}DebounceInput_x = debouncing period in μs (from 1 to 255 μs)InputPinStatusInput_1 = {Low, High}InputPinStatusInput_2 = {Low, High}See "Accessing Features with Sapera++ LT" on page 74.XML features for Trigger Modes, Time Stamp and General Inputs:TriggerMode = {Off = 0, On = 1}TriggerSelector = Select the type of trigger to control. FrameStart currently supported.TriggerSoftware = Generates a software trigger to start the acquisition in any trigger modeTriggerSource = External input or software signal as trigger source {Line2 = 1, Software = 2}TriggerActivation = {LevelLow = 0, LevelHigh = 1, RisingEdge, FallingEdge, AnyEdge}TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal beforestarting exposureTriggerDelayRaw = Absolute delay to apply in us after reception of the trigger signal beforestarting exposureGevTimestampTickFrequency = 64-bit value indicating the number of timestamp clock ticks inone second.GevTimestampControlLatch = Latches the current timestamp value of the device.GevTimestampControlReset = Resets the timestamp count of the device.GevTimestampValue = Latched 64-bit value of the timestamp. Value must first be latched usingGevTimestampControlLatch.CounterSelector = Select counter to configure. Currently only Timestamp is supported.CounterEventSource = Select counter source as {Internal Clock = 0, Input 1 = 1, Input 2 = 2,End of Readout = 3}CounterLineSource = Source for the line to count.CounterReset = Resets the selected Counter.InputLineSelector = Index to general input {input1=0, input2=1}InputLinePolarity = {Active High = 0, Active Low = 1}InputLineDebouncingPeriod = debounce period in μs (from 1 to 255 μs)InputLineValue = Read input line state {low=0, high=1}LineStatus = Current logical state of signal at time of polling {FALSE, TRUE}Line Mode = Indicate if the line is an input or an output.