Genie Monochrome Series-GigE Vision Camera Sapera CamExpert Guide 95Acquisition control button:Click once to start live grab, click again to stop.Single frame grab:Click to acquire one frame from device.Software trigger button:With the I/O control parameters set to Trigger Enabled / Software Triggertype, click to send a single software trigger command.CamExpert display controls:(these do not modify the frame buffer data)Stretch image to fit, set image display to original size, or zoom the image toany size and ratio.Histogram / Profile tool:Select to view a histogram or line/column profile during live acquisition. Output Message pane: Displays messages from CamExpert or the device driver.CamExpert LUT ControlsThe Lookup Table dialog allows you to configure the LUT if it is available on the device. Genie monochromecameras support an 8-bit or 10-bit LUT. To open this dialog, use the Pre-Processing > Lookup Table > Settingmenu command. Note that you must first enable the Lookup Table, otherwise the Setting command will be grayed-out.To select the type of LUT to use, click the LUT Mode Value field; a drop-down list box displays the availablemodes. The Lookup Table dialog displays a graph of the input and output values for the selected LUT. These areCamExpert common examples for LUT operations. A Sapera application can program the Genie LUT for anyrequired LUT operation. See "Lookup Table (LUT)" on page 60 for Genie LUT support.