Normal overload 110% for 1 minuteFrequency converterTypical Shaft Output [kW]P45K45P55K55P75K75P90K90P110110P132132P160160P200200P250250P315315P400400P450450P500500P560560P630630P710710P800800P900900P1M01000P1M21200Typical Shaft Output [HP] at 575 V 50 60 75 100 125 150 200 250 300 350 400 450 500 600 650 750 950 1050 1150 1350IP 00 D3 D3 D3 D3 D3 D3 D3 D4 D4 D4 D4 E2 E2 E2 E2 - - - - -IP 21 / Nema 1 D1 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 E1 E1 E1 E1 F1/F3 6) F1/F36) F1/F36) F2/F46) F2/F46)IP 54 / Nema 12 D1 D1 D1 D1 D1 D1 D1 D2 D2 D2 D2 E1 E1 E1 E1 F1/F3 6) F1/F36) F1/F36) F1/F36) F1/F36)Output currentContinuous (3 x 550 V) [A] 56 76 90 113 137 162 201 253 303 360 418 470 523 596 630 763 889 988 1108 1317Intermittent (3 x 550 V) [A] 62 84 99 124 151 178 221 278 333 396 460 517 575 656 693 839 978 1087 1219 1449Continuous (3 x 690V) [A] 54 73 86 108 131 155 192 242 290 344 400 450 500 570 630 730 850 945 1060 1260Intermittent (3 x 690 V) [A] 59 80 95 119 144 171 211 266 319 378 440 495 550 627 693 803 935 1040 1166 1386Continuous kVA (550 VAC) [kVA] 53 72 86 108 131 154 191 241 289 343 398 448 498 568 600 727 847 941 1056 1255Continuous kVA (575 VAC) [kVA] 54 73 86 108 130 154 191 241 289 343 398 448 498 568 627 727 847 941 1056 1255Continuous kVA (690 VACr) [kVA] 65 87 103 129 157 185 229 289 347 411 478 538 598 681 753 872 1016 1129 1267 1506Max. cable size:(Mains) [mm 2/ AWG] 2) 2x702x2/02x1852x350 mcm4x2404x500 mcm8x2408x500 mcm8x2408x500 mcm(Motor) [mm2 / AWG] 2) 2x702x2/02x1852x350 mcm4x2404x500 mcm8x1508x300 mcm12x15012x300 mcm(Brake) [mm2 / AWG] 2) 2x702x2/02x1852x350 mcm2x1852x350 mcm4x1854x350 mcm6x1856x350 mcmMax. input currentContinuous (3 x 525 V) [A] 60 77 89 110 130 158 198 299 245 299 355 453 504 574 607 743 866 962 1079 1282Continuous (3 x 575 V) [A] 58 74 85 106 124 151 189 286 234 286 339 434 482 549 607 711 828 920 1032 1227Continuous (3 x 690 V) [A] 58 77 87 109 128 155 197 296 240 296 352 434 482 549 607 711 828 920 1032 1227Max. mains pre-fuses1)[A] 125 160 200 200 250 315 350 350 400 500 550 700 700 900 900 2000 2000 2000 2000 2000Environment:Estimated power lossat rated max. load [W] 4) 1458 1717 1913 2262 2662 3114 3612 4292 5156 5821 6149 6449 7249 8727 9673Weight enclosure IP00 [kg] 82 82 82 82 82 82 91 112 123 138 151 221 221 236 277 - - - - -Weight enclosure IP 21 [kg] 6) 96 96 96 96 96 96 104 125 136 151 165 263 263 272 313 1004 1004 1004 1246 1246Weight enclosure IP 54 [kg] 6) 96 96 96 96 96 96 104 125 136 151 165 263 263 272 313 1004 1004 1004 1246 1246Efficiency 3) 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.981) For type of fuse see sectionFuses2) American Wire Gauge3) Measured using 5 m screened motor cables at rated load and rated frequency4) The typical power loss is at normal load conditions and expected to be within +/- 15% (tolerance relates to variety in voltage and cable conditions).Values are based on a typical motor efficiency (eff2/eff3 border line). Lower efficiency motors will also add to the power loss in the frequency converter and vice versa.If the switching frequency is raised from nominal the power losses may rise significantly.and typical control card power consumptions are included. Further options and customer load may add up to 30W to the losses. (Though typically only 4W extra for a fully loaded control card, or options for slot A or slot B, each).Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (+/- 5%).6) Adding the F-enclosure option cabinet (resulting in the F3 and F4 enclosure sizes) adds 295 kgto the estimated weight.3.1.6. Mains Supply 3 x 525 - 690 VAC3. VLT AQUA Selection VLT® AQUA Drive Design Guide52 MG.20.N4.02 - VLT® is a registered Danfoss trademark3