Ordering Numbers: Brake ResistorsMains 380-480 VAC (T4-LP+MP+HP) VLT AQUA DriveSelected resistorStandard IP 20 Aluminium Housed (Flatpack) IP65Duty Cycle 10% 1) Duty Cycle 40% 2)Size: Pmotor Rmin Rbr,nom R rec Pbr max Order no. Period R rec P br max Order no. Period R rec per item Duty cycle Order no.[kW] [Ω] [Ω] [Ω] [kW] 175Uxxxx [s] [Ω] [kW] 175Uxxxx [s] [Ω/W] % 175UxxxxPK37 0.37 620 1098/1360 620 0.065 1840 120 620 0.26 1940 120 830/100 30 1000PK55 0.55 620 739/915 620 0.065 1840 120 620 0.26 1940 120 830/100 20 1000PK75 0.75 601 539/668 620 0.065 1840 120 620 0.26 1940 120 620/100 14 1001PK75 0.75 601 539/668 620 0.065 1840 120 620 0.26 1940 120 620/200 27 0982P1K1 1.1 408 366/453 425 0.095 1841 120 425 0.43 1941 120 430/100 10 1002P1K1 1.1 408 452.8 425 0.095 1841 120 425 0.43 1941 120 430/200 20 0983P1K5 1.5 297 267/330 310 0.25 1842 120 310 0.80 1942 120 310/200 14 0984P2K2 2.2 200 180/223 210 0.29 1843 120 210 1.35 1943 120 210/200 10 0987P3K0 3 145 130/161 150 0.43 1844 120 150 2 1944 120 150/200 7 0989P3K0 3 145 130/161 150 0.43 1844 120 150 2 1944 120 300/200 14 2X09851)P4K0 4 108 97/120 110 0.60 1845 120 110 2 1945 120 240/200 10 2X09861)P5K5 5.5 77 69.4/86 80 0.85 1846 120 80 3 1946 120 160/200 8 2X09881)P7K5 7.5 56 50.3/62.4 65 1 1847 120 65 5 1947 120 130/200 6 2X09901)P11K 11P15K 15 38 38.8/42.1 40 2 1848 120 40 5 1948 120 80/240 5 2x0090P18K 18.5 27 28.1/30.5 30 3 1849 120 30 9 1949 120 72/240 4 2X00911)P22K 22 22 22.6/24.5 25 4 1850 120 25 13 1950 120 - - -P30K 30 18 18.8/20.3 20 4 1851 120 20 13 1951 120 - - -P37K 37 13.5 14.7/15.9 15 5 1852 120 15 16 1952 120 - - -P45K 45 10.8 11.8/12.8 12 6 1853 120 12 19 1953 120 - - -P55K 55 9.8 9.7/10.5 9.8 15 2008 120 9.8 38 2007 120 - - -P75K 75 7.3 7.9/8.6 7.3 13 0069 120 7.3 38 0068 120 - - -P90K 90 5.7 5.2/6.2 6 15 0067 120 4.7 45 0066 120 - - -P110 110 3.6 5.2 3.8 22 1960 300 3.8 75 2X0072 3) 600 - - -P132 132 3 4.2 3.2 27 1961 300 3.2 90 2X0073 3) 600 - - -P160 160 2.5 3.5 2.6 32 1962 300 2.6 112 2X0074 3) 600 - - -P200 200 2 2.9 2.1 39 1963 300 2.1 135 3X0075 4) 600 - - -P250 250 1.6 2.3 3.3 56 2X1061 3) 300 3.3 NA 600P315 315 1.2 1.9 2.6 72 2X1062 3) 300 2.6 NA 600P355 355 1.2 1.5 2.6 72 2X1062 3) 300 2.6 NA 600P400 400 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P450 450 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P500 500 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P560 560 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P630 630 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P710 710 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P800 800 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 600P1M0 1000 1.2 1.3 2.6 72 2X1062 3, 5) 300 2.6 NA 6001a) 10% duty cycle based on 160% braking torque for 30 seconds during 300 second cycles.2) 40% duty cycle based on 100% braking torque for 240 seconds during 600 second cycles.3) Order two resistors as listed.4) Order three resistors as listed.5) Braking torque reduced (below 160%).VLT® AQUA Drive Design Guide 4. How to OrderMG.20.N4.02 - VLT® is a registered Danfoss trademark 914